Evidence map›Paper›PMID 39825071›Full record

ArticleThe international journal of cardiovascular imaging2025

Effectiveness of single-energy metal artifact reduction algorithm in CT: application to contrast-enhanced CT with EVAR and coil embolization.

Junji Mochizuki, Noriko Oyama-Manabe, Fumi Kato, Hideki Takahashi, Osamu Manabe, Akihiro Sawada, Homare Okamura, Mitsunori Nakano, Atsushi Yamaguchi

Abstract read
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Junji MochizukiDepartment of Radiology, Jichi Medical University Saitama Medical Center, 1-847 Amanuma-Cho, Omiya- Ku, Saitama, 330-8503, Japan. mochizuki.j@minaminohc.jp.ORCID https://orcid.org/0000-0001-9548-1430
Noriko Oyama-ManabeDepartment of Radiology, Jichi Medical University Saitama Medical Center, 1-847 Amanuma-Cho, Omiya- Ku, Saitama, 330-8503, Japan.
Fumi KatoDepartment of Radiology, Jichi Medical University Saitama Medical Center, 1-847 Amanuma-Cho, Omiya- Ku, Saitama, 330-8503, Japan.
Hideki TakahashiDepartment of Radiology, Jichi Medical University Saitama Medical Center, 1-847 Amanuma-Cho, Omiya- Ku, Saitama, 330-8503, Japan.
Osamu ManabeDepartment of Radiology, Jichi Medical University Saitama Medical Center, 1-847 Amanuma-Cho, Omiya- Ku, Saitama, 330-8503, Japan.
Akihiro SawadaDepartment of Radiology, Jichi Medical University Saitama Medical Center, 1-847 Amanuma-Cho, Omiya- Ku, Saitama, 330-8503, Japan.
Homare OkamuraDepartment of Cardiovascular Surgery, Jichi Medical University Saitama Medical Center, 1- 847 Amanuma-Cho, Omiya-Ku, Saitama, 330-8503, Japan.
Mitsunori NakanoDepartment of Cardiovascular Surgery, Jichi Medical University Saitama Medical Center, 1- 847 Amanuma-Cho, Omiya-Ku, Saitama, 330-8503, Japan.
Atsushi YamaguchiDepartment of Cardiovascular Surgery, Jichi Medical University Saitama Medical Center, 1- 847 Amanuma-Cho, Omiya-Ku, Saitama, 330-8503, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to evaluate the efficacy of the single-energy metal artifact reduction (SEMAR) algorithm in reducing metal artifacts and enhancing image quality in contrast-enhanced computed tomography (CT) for patients undergoing endovascular aneurysm repair (EVAR) with coil embolization. Thirty-eight patients (mean age 81.0 ± 6 years; 31 men, 7 women) who underwent contrast-enhanced CT following EVAR and internal iliac artery coil embolization between September 2022 and May 2023 were retrospectively analyzed. The Artifact Index (AI) quantified metallic artifacts from internal iliac artery aneurysm coils in CT images, calculated from the standard deviation of the artifact-containing region relative to a reference region. CT values of the external iliac artery at the same slice were also evaluated and compared. Two radiologists independently performed qualitative assessments of SEMAR and non-SEMAR images. SEMAR significantly reduced metal artifacts, decreasing the AI from 171.9 ± 74.5 HU to 35.8 ± 16.9 HU (p < 0.001). The mean CT values of the external iliac artery were similar for SEMAR (259.4 ± 63.7 HU) and non-SEMAR (257.1 ± 63.6 HU, indicating no significant difference. Qualitative assessment scores improved significantly with SEMAR (from 1.0 ± 0.0 to 2.5 ± 0.5; p < 0.001), enhancing visualization of internal iliac artery aneurysms. Interobserver agreement was high (κ = 0.83). The SEMAR algorithm effectively reduces metal artifacts in contrast-enhanced CT, significantly enhancing image quality without altering adjacent artery CT values. These improvements enhance the image quality of post-operative assessments in patients undergoing EVAR with coil embolization.

Indexed as

AlgorithmsAortic Aneurysm, AbdominalAortographyArtifactsComputed Tomography AngiographyContrast MediaEmbolization, TherapeuticEndovascular ProceduresIliac AneurysmMetalsMultidetector Computed TomographyRadiographic Image Interpretation, Computer-AssistedAgedAged, 80 and overFemaleHumansContrast MediaMetalsCoil embolizationComputed tomographyEndovascular aortic repairMetal artifact reduction

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.