ArticlePloS one2025
Central venous pressure as a method of optimising atrio-ventricular delay after cardiac surgery.
Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
introductionHaemodynamic atrioventricular delay (AVD) optimisation has primarily focussed on signals that are not easy to acquire from a pacing system itself, such as invasive left ventricular catheterisation or arterial blood pressure (ABP). In this study, standard clinical central venous pressure (CVP) signals are tested as a potential alternative.
methodsSixteen patients with a temporary pacemaker after cardiac surgery were studied. AV delay optimisation was performed by alternating between a reference AVD of 120ms and tested settings ranging from 40 to 280ms, with 8 replicates for each setting. Alongside (a) the raw data, three methods of correcting for respiration were tested: (b) limiting analysis to a respiratory cycle, (c) asymmetric least squares (ALS) and (d) discrete wavelet transform (DWT). The utility of a quality control step was tested.
resultsCVP signals were a mirror image of the systolic ABP signals: The four R values were -0.674, -0.692, -0.631, -0.671 respectively (all p<0.001). With quality control, the mirror image was best for DWT (R = -0.76, p<0.001), with the CVP and ABP optima agreeing well (R = 0.78, p<0.001). The automated quality control signal correctly predicted the gap between the AVD optima calculated from ABP and CVP (R = 0.8, p<0.001).
conclusionsCentral venous pressure signals could be used to optimise AVD, because they have a reliable inverse relationship with ABP when pacemaker settings undergo protocolised testing. However, protocols need careful design to circumvent spontaneous biological variability.