Evidence map›Paper›PMID 39821728›Full record

ArticleEJNMMI physics2025

Improving timing resolution of BGO for TOF-PET: a comparative analysis with and without deep learning.

Francis Loignon-Houle, Nicolaus Kratochwil, Maxime Toussaint, Carsten Lowis, Gerard Ariño-Estrada, Antonio J Gonzalez, Etiennette Auffray, Roger Lecomte

Abstract read
In one paragraph

Article in EJNMMI physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Current Status of Cherenkov-Based Gamma Detectors for TOF-PET and Proton Range Verification.IEEE transactions on radiation and plasma medical sciences · 2026
    Article
  5. High-performance dual-ended SiPM readout for TOF-PET with BGO and LYSO:Ce.IEEE transactions on radiation and plasma medical sciences · 2025
    Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Francis Loignon-HouleInstituto de Instrumentación para Imagen Molecular, Centro Mixto CSIC-Universitat Politècnica de València, Camino de Vera, Valencia, 46002, Spain. floignon@i3m.upv.es.ORCID http://orcid.org/0000-0001-8931-2016
Nicolaus KratochwilDepartment of Biomedical Engineering, University of California Davis, One Shields Ave., Davis, California, 95616, USA.
Maxime ToussaintSherbrooke Molecular Imaging Center and Department of Nuclear Medicine and Radiobiology, Université de Sherbrooke, 12th Avenue N, Sherbrooke, J1H 5N4, Québec, Canada.
Carsten LowisCERN, Department EP-CMX, Esplanade des Particules 1, Meyrin, 1217, Switzerland.
Gerard Ariño-EstradaDepartment of Biomedical Engineering, University of California Davis, One Shields Ave., Davis, California, 95616, USA.
Antonio J GonzalezInstituto de Instrumentación para Imagen Molecular, Centro Mixto CSIC-Universitat Politècnica de València, Camino de Vera, Valencia, 46002, Spain.
Etiennette AuffrayCERN, Department EP-CMX, Esplanade des Particules 1, Meyrin, 1217, Switzerland.
Roger LecomteSherbrooke Molecular Imaging Center and Department of Nuclear Medicine and Radiobiology, Université de Sherbrooke, 12th Avenue N, Sherbrooke, J1H 5N4, Québec, Canada.

Funding

Fonds de recherche du Québec - Nature et technologies 2022-2023 - B3X - 316340Natural Sciences and Engineering Research Council of Canada BP - 567696 - 2022Natural Sciences and Engineering Research Council of Canada RGPIN-2019-06187
6 · The paper itself

Abstract

backgroundThe renewed interest in BGO scintillators for TOF-PET is driven by the improved Cherenkov photon detection with new blue-sensitive SiPMs. However, the slower scintillation light from BGO causes significant time walk with leading edge discrimination (LED), which degrades the coincidence time resolution (CTR). To address this, a time walk correction (TWC) can be done by using the rise time measured with a second threshold. Deep learning, particularly convolutional neural networks (CNNs), can also enhance CTR by training with digitized waveforms. It remains to be explored how timing estimation methods utilizing one (LED), two (TWC), or multiple (CNN) waveform data points compare in CTR performance of BGO scintillators.

resultsIn this work, we compare classical experimental timing estimation methods (LED, TWC) with a CNN-based method using the signals from BGO crystals read out by NUV-HD-MT SiPMs and high-frequency electronics. For

conclusionsThe higher complexity of waveform digitization needed for CNNs could potentially be mitigated by adopting a simpler two-threshold approach, which appears to currently capture most of the essential information for improving CTR in longer BGO crystals. Other innovative deep learning models and training strategies may nonetheless contribute further in a near future to harnessing increasingly discernible timing features in TOF-PET detector signals.

Indexed as

BGOCherenkovDeep learningFast timingTime-of-flight PETTime resolution

Identifiers

PMID39821728
PMCPMC11739447

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.