ArticleNan fang yi ke da xue xue bao = Journal of Southern Medical University2025
A low-dose CT reconstruction method using sub-pixel anisotropic diffusion.
Article in Nan fang yi ke da xue xue bao = Journal of Southern Medical University, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
objectivesWe present a new low-dose CT reconstruction method using sub-pixel and anisotropic diffusion.
methodsThe sub-pixel intensity values and their second-order differences were obtained using linear interpolation techniques, and the new gradient information was then embedded into an anisotropic diffusion process, which was introduced into a penalty-weighted least squares model to reduce the noise in low-dose CT projection data. The high-quality CT image was finally reconstructed using the classical filtered back-projection (FBP) algorithm from the estimated data.
resultsIn the Shepp-Logan phantom experiments, the structural similarity (SSIM) index of the CT image reconstructed by the proposed algorithm, as compared with FBP, PWLS-Gibbs and PWLS-TV algorithms, was increased by 28.13%, 5.49%, and 0.91%, the feature similarity (FSIM) index was increased by 21.08%, 1.78%, and 1.36%, and the root mean square error (RMSE) was reduced by 69.59%, 18.96%, and 3.90%, respectively. In the digital XCAT phantom experiments, the SSIM index of the CT image reconstructed by the proposed algorithm, as compared with FBP, PWLS-Gibbs and PWLS-TV algorithms, was increased by 14.24%, 1.43% and 7.89%, the FSIM index was increased by 9.61%, 1.78% and 5.66%, and the RMSE was reduced by 26.88%, 9.41% and 18.39%, respectively. In clinical experiments, the SSIM index of the image reconstructed using the proposed algorithm was increased by 19.24%, 15.63% and 3.68%, the FSIM index was increased by 4.30%, 2.92% and 0.43%, and the RMSE was reduced by 44.60%, 36.84% and 15.22% in comparison with FBP, PWLS-Gibbs and PWLS-TV algorithms, respectively.
conclusionsThe proposed method can effectively reduce the noises and artifacts while maintaining the structural details in low-dose CT images.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.