Evidence map›Paper›PMID 39819273›Full record

ArticleBMC anesthesiology2025

Comparison of integrated versus parallel continuous renal replacement therapy combined with veno-venous extracorporeal membrane oxygenation in patients with COVID-19 ARDS.

Kristina Schönfelder, Felix Helmenstein, Frank Herbstreit, Johanna Reinold, Andreas Kribben, Michael Jahn, Justa Friebus-Kardash

Abstract readComparative Study
In one paragraph

Article in BMC anesthesiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Kristina SchönfelderDepartment of Nephrology, University of Duisburg-Essen, University Hospital Essen, Essen, Germany.
Felix HelmensteinDepartment of Nephrology, University of Duisburg-Essen, University Hospital Essen, Essen, Germany.
Frank HerbstreitDepartment of Anaesthesiology, University of Duisburg-Essen, University Hospital Essen, Essen, Germany.
Johanna ReinoldDepartment of Nephrology, University of Duisburg-Essen, University Hospital Essen, Essen, Germany.
Andreas KribbenDepartment of Nephrology, University of Duisburg-Essen, University Hospital Essen, Essen, Germany.
Michael Jahn *Department of Nephrology, University of Duisburg-Essen, University Hospital Essen, Essen, Germany.
Justa Friebus-Kardash *Department of Nephrology, University of Duisburg-Essen, University Hospital Essen, Essen, Germany. justa.friebus-kardash@uk-essen.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAcute kidney injury (AKI) is a common complication of acute respiratory distress syndrome (ARDS) and multiple organ dysfunction syndrome (MODS) in patients receiving extracorporeal membrane oxygenation (ECMO) support, leading to requirement of continuous renal replacement therapy (CRRT) in 70% of ECMO patients. Parallel arrangement of CRRT and ECMO circuits is common in adult patients. However, CRRT may also be integrated directly into the ECMO circuit. This study compares the safety of both approaches.

methodsThis retrospective analysis included 105 patients treated with continuous veno-venous haemodiafiltration and veno-venous ECMO (Cardiohelp©) for COVID-19-induced ARDS between April 2020 and December 2021. Of these, 48 patients received a parallel connected CRRT running independently from ECMO (parallel approach), while in 57 patients, CRRT was integrated into the ECMO circuit (integrated approach) by connecting the CRRT access line to the post-oxygenator port and the CRRT return line to the pre-oxygenator position. Local protocol for risk assessment of this device combination mandated a maximum return line pressure below 250 mmHg in the CRRT system.

resultsAt CRRT initiation, the integrated group had significantly higher median pressures in CRRT lines compared to the parallel approach group (access line 110 mmHg vs. -25 mmHg, return line 170 mmHg vs. 50 mmHg; p < 0.01). However, median transmembrane pressures were similar between both groups (20 mmHg vs. 20 mmHg, p = 0.16). In-hospital mortality (p = 0.99), catheter associated infections (p = 0.47), bacteraemia (p = 0.96), filter clotting (p = 0.58) and unplanned CRRT system changes (p = 0.45) within the first 72 h of CRRT were comparable between both groups. The integrated group exhibited higher rates of bleeding events (37% vs. 23%; p = 0.08). Thromboembolism occurred in four cases in the integrated group, while one pneumothorax was observed in the parallel group. No cases of air embolism, device associated haemolysis or blood leakage was documented.

conclusionsDespite higher pressures in CRRT lines, the integrated approach provided comparable safety to the parallel approach. In case of hygienically challenging settings (such as the COVID-19 pandemic), the minimization of extracorporeal accesses and the streamlining of alarm management are decisive factors in providing intensive care medicine. Therefore, the integrated configuration of CRRT into the ECMO circuit can be advantageous in daily intensive care medicine.

Indexed as

Acute Kidney InjuryContinuous Renal Replacement TherapyCOVID-19Extracorporeal Membrane OxygenationRenal Replacement TherapyRespiratory Distress SyndromeAdultAgedFemaleHemodiafiltrationHumansMaleMiddle AgedRetrospective StudiesARDSContinuous renal replacement therapy (CRRT)COVID 19Device combinationExtracorporeal membrane oxygenation (ECMO)Integrated connectionMedical devicesParallel connectionSafety

Identifiers

PMID39819273
PMCPMC11737070

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.