Evidence map›Paper›PMID 39816714›Full record

ArticleJournal of clinical orthopaedics and trauma2025

Guide-wire and K-wire readjustment jig for osteotomy and osteosynthesis: An instrument.

Sandeep Patil, Sachin Patil, Punam Patil

Abstract read
In one paragraph

Article in Journal of clinical orthopaedics and trauma, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Sandeep PatilJoints and Spine Clinic, Mahavir Nagar, Kandivali West, Mumbai, 400067, India.
Sachin PatilJoints and Spine Clinic, Mahavir Nagar, Kandivali West, Mumbai, 400067, India.
Punam PatilJoints and Spine Clinic, Mahavir Nagar, Kandivali West, Mumbai, 400067, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Numerous orthopaedic procedures including dynamic hip screw plating and various osteotomies require placement of a reference guide pin or K wire to direct bone cuts or for drilling screw holes. Appropriate positioning of these wires is a critical component of surgery. Irrespective of whether one is a seasoned surgeon or an apprentice, these wires often need repositioning and readjustment. Parallel wire positioning is needed even during procedures like osteotomies or patellar fracture fixation. Though there are several tools available to help with accurate placement of wires and saving operating time, there are very few tools which can actually control the direction or angulation of the wire. The ones which are available are usually difficult to use, are bulky, have long attachments arms or have too many fine adjustments. We propose a device that not only directs the positioning of the parallel wires but also helps with a 360-degree correction in direction of the wrongly positioned wire. It is a multipurpose jig that can be used in patella fracture, inter-trochanteric fracture femur, fracture neck of femur, osteotomies around knee, elbow and distal femur, etc. Material and methods: We proposed, designed and manufactured a new device for the guide wire insertion. Our jig design has three tunnels. Two tunnels, primary and secondary run parallel to each other and the oblique tunnel runs at an angle and is positioned 7 mm away from the parallel tunnel at one end and shares a common opening with the secondary tunnel on opposite end. Other similar jigs either have only parallel tunnels (primary and secondary) or an oblique tunnel which is at the far end of metal bar, making it difficult to be used to correct the angular direction of the guidewire in reference to primary or secondary wire. Results and conclusions: Using our newer device, wires can be guided in all directions and in all planes (sagittal, coronal, axial, and 360°). Correction of the wire direction using this jig is significantly easier and faster, a process which can take anywhere between 15 min and an hour of surgical time for a beginner orthopaedic surgeon. The need for multiple repeated attempts to insert wires, resulting in a bone void and damage to the surrounding structures, is minimised or eliminated. Applications include a variety of surgical procedures of osteosynthesis and osteotomies. In conclusion, our device is easier to use as it is smaller in size and available in different sizes and angles. It not only avoids bone loss and fragmentation due to repetitive insertion of wires but also improves the accuracy of primary reference wire placement or revision of its direction.

Indexed as

Guide-wireJigK-wireOsteotomyPatellaReadjustment

Identifiers

PMID39816714
PMCPMC11731509

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.