ArticleScientific reports2025
Identification and correction of phase delay errors for hemispherical resonator gyroscopes.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Analyzing the geometric dependence of thermoelastic Q-factor in micro hemispherical resonators via a data-augmented CNN-transformer model.Microsystems & nanoengineering · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The phase-delay error of the circuit system is the primary source of the output error observed in the hemispherical resonator gyroscope (HRG). Additionally, the temperature-dependent nature of the phase-delay error results in a deterioration of the initial calibration parameters, which, in turn, significantly impairs the performance of the gyroscope in its intended application. This paper proposes a self-calibration method to effectively suppress the impact of phase-delay error on the application performance of gyroscopes. Firstly, based on the analysis of the influence of phase-delay error on the performance of the whole-angle mode HRG, a sinusoidal interference signal with a small amplitude is introduced into the quadrature control loop of the gyroscope. Then, the angular rate signal is demodulated and calculated to obtain the phase-delay error of the system, which is employed as the compensation value of the reference phase of the PLL to offset the phase-delay error of the circuit system in real-time. The experimental results demonstrate that after the phase-delay error is self-calibrated, the zero-bias output error of the gyroscope is reduced by 5 times, the bias instability is improved by 37.7%, and the self-calibration method of the phase-delay error presented is more strongly robust to temperature changes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.