Evidence map›Paper›PMID 39811751›Full record

ArticleEuropean heart journal. Case reports2025

Complications of transvenous lead extraction-focus on tricuspid valve damage: a case report.

Anna Jargieło, Maciej Sterliński, Artur Oręziak, Radosław Pracoń, Piotr Kołsut

Abstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Removal of tine-based leadless pacemakers: insights from a large multicentre experience.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
    Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Anna Jargieło1st Department of Arrhythmia, National Institute of Cardiology, 42 Alpejska Street, 04-628 Warsaw, Poland.ORCID https://orcid.org/0009-0008-9300-4655
Maciej Sterliński1st Department of Arrhythmia, National Institute of Cardiology, 42 Alpejska Street, 04-628 Warsaw, Poland.
Artur Oręziak1st Department of Arrhythmia, National Institute of Cardiology, 42 Alpejska Street, 04-628 Warsaw, Poland.
Radosław Pracoń1st Department of Arrhythmia, National Institute of Cardiology, 42 Alpejska Street, 04-628 Warsaw, Poland.
Piotr Kołsut1st Department of Arrhythmia, National Institute of Cardiology, 42 Alpejska Street, 04-628 Warsaw, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Transvenous lead extraction (TLE) has become an essential component of lead management strategies, but it carries the risk of severe complications, including damage to the tricuspid valve. Currently, there are no established predictors that can help prevent these complications. Case summary: An 84-year-old male with a dual-chamber pacemaker was admitted to the hospital due to a pocket fistula resulting from a local infection. Approximately 1 year prior, he underwent the implantation of a new ventricular lead and pacemaker replacement due to lead damage and battery depletion. Another lead had been abandoned. The patient underwent a procedure to remove the entire pacing system, which was complicated by tricuspid leaflet avulsion, resulting in acute and severe tricuspid regurgitation. A biological valve was successfully implanted to replace the damaged valve. Twenty days later, a new pacing system was implanted, which included one atrial lead and another positioned in the posterolateral coronary vein of the left ventricle. Post-procedural transthoracic echocardiography (TTE) showed the biological valve in place at the tricuspid orifice, with no regurgitation and preserved ejection fraction. Following recovery, the patient was discharged in good condition. Discussion: While pre-procedural TTE and intra-procedural transesophageal echocardiography are commonly used to identify lead-induced tricuspid insufficiency, they often do not clarify the underlying mechanisms or predict potential complications during TLE. To address this issue safely, further research into new imaging techniques is necessary, as some existing methods may not be adequate in certain situations.

Indexed as

Cardiac implantable electronic deviceCase reportDual-chamber pacemakerLead-induced tricuspid insufficiencyTransvenous lead extractionTricuspid regurgitation

Identifiers

PMID39811751
PMCPMC11732274

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.