Evidence map›Paper›PMID 39811475›Full record

ArticleWearable technologies2024

Sensorless model-based tension control for a cable-driven exosuit.

Elena Bardi, Adrian Esser, Peter Wolf, Marta Gandolla, Emilia Ambrosini, Alessandra Pedrocchi, Robert Riener

Abstract read
In one paragraph

Article in Wearable technologies, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Elena BardiWeCobot Lab, Polo territoriale di Lecco, Politecnico di Milano, Milano, Italy.ORCID https://orcid.org/0000-0002-4353-1456
Adrian EsserSensory Motor Systems Lab, Department of Health Sciences and Technology, ETH Zürich, Zürich, Switzerland.ORCID https://orcid.org/0009-0005-6191-3801
Peter WolfSensory Motor Systems Lab, Department of Health Sciences and Technology, ETH Zürich, Zürich, Switzerland.
Marta GandollaWeCobot Lab, Polo territoriale di Lecco, Politecnico di Milano, Milano, Italy.
Emilia AmbrosiniWeCobot Lab, Polo territoriale di Lecco, Politecnico di Milano, Milano, Italy.
Alessandra PedrocchiWeCobot Lab, Polo territoriale di Lecco, Politecnico di Milano, Milano, Italy.
Robert RienerSensory Motor Systems Lab, Department of Health Sciences and Technology, ETH Zürich, Zürich, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cable-driven exosuits have the potential to support individuals with motor disabilities across the continuum of care. When supporting a limb with a cable, force sensors are often used to measure tension. However, force sensors add cost, complexity, and distal components. This paper presents a design and control approach to remove the force sensor from an upper limb cable-driven exosuit. A mechanical design for the exosuit was developed to maximize passive transparency. Then, a data-driven friction identification was conducted on a mannequin test bench to design a model-based tension controller. Seventeen healthy participants raised and lowered their right arms to evaluate tension tracking, movement quality, and muscular effort. Questionnaires on discomfort, physical exertion, and fatigue were collected. The proposed strategy allowed tracking the desired assistive torque with a root mean square error of 0.71 Nm (18%) at 50% gravity support. During the raising phase, the electromyography signals of the anterior deltoid, trapezius, and pectoralis major were reduced on average compared to the no-suit condition by 30, 38, and 38%, respectively. The posterior deltoid activity was increased by 32% during lowering. Position tracking was not significantly altered, whereas movement smoothness significantly decreased. This work demonstrates the feasibility and effectiveness of removing the force sensor from a cable-driven exosuit. A significant increase in discomfort in the lower neck and right shoulder indicated that the ergonomics of the suit could be improved. Overall this work paves the way toward simpler and more affordable exosuits.

Indexed as

ControlExosuitsHuman-robot interactionRehabilitationroboticsSoft wearable robotics

Identifiers

PMID39811475
PMCPMC11729527

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.