Evidence map›Paper›PMID 39810810›Full record

ArticleGMS hygiene and infection control2024

Achieving room air quality of room class Ib in the aseptic area using a mobile sterile ventilation unit in a room class II surgical unit.

Dorothee Boppre, Martin Exner, Colin M Krüger, Hannes Schuler, Michael Wendt, Julian-Camill Harnoss, Axel Kramer

Abstract read
In one paragraph

Article in GMS hygiene and infection control, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Dorothee BoppreInstitute of Hygiene and Environmental Medicine, University Medicine Greifswald, Germany.
Martin ExnerInstitute of Hygiene and Public Health, Bonn, Germany.
Colin M KrügerDepartment of Surgery, Centre of Robotics, University Hospital Ruedersdorf, Medical University Brandenburg Theodor-Fontane, Ruedersdorf, Germany.
Hannes SchulerInstitute of Hygiene and Environmental Medicine, University Medicine Greifswald, Germany.
Michael WendtClinic and outpatient clinic for Anaesthesiology and Intensive Care Medicine, University Medicine Greifswald, Germany.
Julian-Camill HarnossDepartment of General, Visceral and Transplantation Surgery, University Hospital Heidelberg, Germany.
Axel KramerInstitute of Hygiene and Environmental Medicine, University Medicine Greifswald, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Room air class (RC) Ib may be necessary for surgical procedures in aseptic working areas. The aim of the study was to examine whether a mobile, three-stage sterile ventilation unit (MSVU) can replace a room ventilation system (RVS) with turbulent mixed flow (TMF) in the area of the operating field and on the instrument table from hygienic-microbiological point of view. Method: During 26 surgeries (varicose vein stripping or treatment of umbilical and inguinal hernias), the microbial load was recorded at 4 measuring points (M1-M4) during regular operations by setting up sedimentation plates and measuring the particle concentration. Measuring points M1 and M2 were located at the beginning and the end of the instrument table, measuring point M3 next to the operating field and measuring point M4 outside the sterilely ventilated area approx. 135 cm from the operating field. The measured values were compared with results with simulated, incorrect positioning and with MSVU not switched on. Results: The number of people and the duration of the operation did not differ between the 3 measurement situations.The MSVU achieved a significant reduction in the number of sedimented colony-forming units (CFU) at M1 by 88.4%, at M2 by 91.5% and at M3 by 65.2%. At measuring point M4, the values did not differ between MSVU switched on or off. Even with an unacceptably increased distance between the MSVU and the instrument table, the difference at measuring points M1, M2 and M3 was still significant in comparison with MSVU switched off. Coagulase-negative staphylococci were predominantly detected, followed by Conclusion: With the MSVU, a reduction of the microbial load and the particle count in the room air was achieved in the area of the operating field and on the instrument table during operation in an RC II surgical unit, which can be categorised as sufficient for operations in RC Ib. With the aid of an MSVU, operations with a high risk of surgical sire infections can also be carried out in surgical units of RC II from hygienic-microbiological point of view. The MSVU is an organisationally flexible and economically interesting, safe and sustainable option in terms of the microbiological load and particle count in the operating field and instrument table instead of an RVS that ventilates the entire room. In times of increasing outpatientisation of surgical services, MSVU is a promising option for outpatient surgical units in particular.

Indexed as

alternative for room ventilation systemselimination of microorganismselimination of particlesmobile sterile ventilation unitroom class Ib

Identifiers

PMID39810810
PMCPMC11730182

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.