Evidence map›Paper›PMID 39807032›Full record

ArticleJournal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.]2025

Accuracy of Guided Dual Technique in Esthetic Crown Lengthening: A Prospective Case-Series Study.

Meritxell Enfedaque-Prat, Albert González-Barnadas, Adrià Jorba-García, Javi Vilarrasa, Jorge Toledano-Serrabona, Rui Figueiredo, Eduard Valmaseda-Castellón, Octavi Camps-Font

Abstract read
In one paragraph

Article in Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.], 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Meritxell Enfedaque-PratOral Surgery and Implantology, Faculty of Medicine and Health Sciences of the University of Barcelona, Barcelona, Spain.
Albert González-BarnadasPeriodontology and Peri-Implant Diseases, Faculty of Medicine and Health Sciences of the University of Barcelona, Barcelona, Spain.ORCID https://orcid.org/0000-0002-0782-9896
Adrià Jorba-GarcíaOral Surgery and Implantology, Faculty of Medicine and Health Sciences of the University of Barcelona, Barcelona, Spain.ORCID https://orcid.org/0000-0003-2369-0326
Javi VilarrasaDepartment of Periodontology, International University of Catalonia, Barcelona, Spain.
Jorge Toledano-SerrabonaOral Surgery and Implantology, Faculty of Medicine and Health Sciences of the University of Barcelona, Barcelona, Spain.
Rui FigueiredoOral Surgery and Implantology, Faculty of Medicine and Health Sciences of the University of Barcelona, Barcelona, Spain.ORCID https://orcid.org/0000-0002-2122-6530
Eduard Valmaseda-CastellónOral Surgery and Implantology, Faculty of Medicine and Health Sciences of the University of Barcelona, Barcelona, Spain.
Octavi Camps-FontPeriodontology and Peri-Implant Diseases, Faculty of Medicine and Health Sciences of the University of Barcelona, Barcelona, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study aimed to evaluate the efficacy and safety of a digitally guided dual technique during esthetic crown lengthening surgery. In addition, patient satisfaction and patient-reported outcomes were assessed. MATERIALS AND

methodsA prospective case series study was conducted. Cone-beam computed tomography and intraoral scans were used to design surgical guides, which were manufactured via 3D printing. The primary outcome was surgical accuracy, assessed by measuring the distance between the planned and final gingival margin positions using overlapping intraoral scans. Secondary outcomes included clinical crown length, gingival margin stability, pain, and patient satisfaction. Statistical analyses were performed using multilevel linear regression models, with significance set at p < 0.05.

resultsTen participants (87 teeth) were treated without complications. The mean duration of surgery was 66.5 min. The overall absolute deviation was 0.56 mm (95% CI: 0.48 to 0.65) at 6 months postoperatively. Clinical crown length increased significantly from baseline to the end of surgery (p < 0.001), with minimal reduction at 6 months (p = 0.479). Patient-reported outcomes indicated mild postoperative pain and high satisfaction with esthetic results.

conclusionsThe digitally guided dual technique for esthetic crown lengthening surgery is safe and effective, providing highly accurate outcomes. The technique also results in excellent patient satisfaction. CLINICAL SIGNIFICANCE: The use of digitally guided dual techniques for ACL surgery enhances precision and safety, leading to highly accurate outcomes and improved patient satisfaction. This approach could be beneficial in clinical settings to ensure better esthetic and functional results.

Indexed as

Crown LengtheningEsthetics, DentalAdultCone-Beam Computed TomographyFemaleHumansMaleMiddle AgedPatient SatisfactionPrinting, Three-DimensionalProspective Studiesaltered passive eruptionesthetic crown lengtheningguided surgerypatient reported outcomes

Identifiers

PMID39807032
PMCPMC12087944

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.