ArticleInternational journal of computer assisted radiology and surgery2025
Shape-matching-based fracture reduction aid concept exemplified on the proximal humerus-a pilot study.
Article in International journal of computer assisted radiology and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Emerging Technologies for Assisted Fracture Reduction: A Systematic Review.Annals of biomedical engineering · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
purposeOptimizing fracture reduction quality is key to achieve successful osteosynthesis, especially for epimetaphyseal regions such as the proximal humerus (PH), but can be challenging, partly due to the lack of a clear endpoint. We aimed to develop the prototype for a novel intraoperative C-arm-based aid to facilitate true anatomical reduction of fractures of the PH.
methodsThe proposed method designates the reduced endpoint position of fragments by superimposing the outer boundary of the premorbid bone shape on intraoperative C-arm images, taking the mirrored intact contralateral PH from the preoperative CT scan as a surrogate. The accuracy of the algorithm was tested on 60 synthetic C-arm images created from the preoperative CT images of 20 complex PH fracture cases (Dataset A) and on 12 real C-arm images of a prefractured human anatomical specimen (Dataset B). The predicted outer boundary shape was compared with the known exact solution by (1) a calculated matching error and (2) two experienced shoulder trauma surgeons.
resultsA prediction accuracy of 88% (with 73% 'good') was achieved according to the calculation method and an 87% accuracy (68% 'good') by surgeon assessment in Dataset A. Accuracy was 100% by both assessments for Dataset B.
conclusionBy seamlessly integrating into the standard perioperative workflow and imaging, the intuitive shape-matching-based aid, once developed as a medical device, has the potential to optimize the accuracy of the reduction of PH fractures while reducing the number of X-rays and surgery time. Further studies are required to demonstrate the applicability and efficacy of this method in optimizing fracture reduction quality.
Indexed as
Identifiers
39806227What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.