Evidence map›Paper›PMID 39803347›Full record

ArticlePhysics and imaging in radiation oncology2024

Head and neck automatic multi-organ segmentation on Dual-Energy Computed Tomography.

Anh Thu Lê, Killian Sambourg, Roger Sun, Nicolas Deny, Vjona Cifliku, Rahimeh Rouhi, Eric Deutsch, Nathalie Fournier-Bidoz, Charlotte Robert

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Anh Thu LêUniversité Paris-Saclay, Gustave Roussy, Inserm, Molecular Radiotherapy and Therapeutic Innovation, U1030, 94800 Villejuif, France.
Killian SambourgUniversité Paris-Saclay, Gustave Roussy, Inserm, Molecular Radiotherapy and Therapeutic Innovation, U1030, 94800 Villejuif, France.
Roger SunUniversité Paris-Saclay, Gustave Roussy, Inserm, Molecular Radiotherapy and Therapeutic Innovation, U1030, 94800 Villejuif, France.
Nicolas DenyDepartment of Radiation Oncology, Gustave Roussy Cancer Campus, Villejuif, France.
Vjona CiflikuUniversité Paris-Saclay, Gustave Roussy, Inserm, Molecular Radiotherapy and Therapeutic Innovation, U1030, 94800 Villejuif, France.
Rahimeh RouhiUniversité Paris-Saclay, Gustave Roussy, Inserm, Molecular Radiotherapy and Therapeutic Innovation, U1030, 94800 Villejuif, France.
Eric DeutschUniversité Paris-Saclay, Gustave Roussy, Inserm, Molecular Radiotherapy and Therapeutic Innovation, U1030, 94800 Villejuif, France.
Nathalie Fournier-BidozDepartment of Radiation Oncology, Gustave Roussy Cancer Campus, Villejuif, France.
Charlotte RobertUniversité Paris-Saclay, Gustave Roussy, Inserm, Molecular Radiotherapy and Therapeutic Innovation, U1030, 94800 Villejuif, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose: Deep-learning-based automatic segmentation is widely used in radiation oncology to delineate organs-at-risk. Dual-energy CT (DECT) allows the reconstruction of enhanced contrast images that could help with manual and auto-delineation. This paper presents a performance evaluation of a commercial auto-segmentation software on image series generated by a DECT. Material and methods: Different types of DECT images from seventy four head-and-neck (HN) patients were retrieved, including polyenergetic images at different voltages [80 kV reconstructed with a kernel corresponding to the commercial algorithm DirectDensity™ (PEI80-DD), 80 kV (PEI80), 120 kV-mixed (PEI120)] and a virtual-monoenergetic image at 40 keV (VMI40). Delineations used for treatment planning were considered as ground truth (GT) and were compared with the auto-segmentations performed on the 4 DECT images. A blinded qualitative evaluation of 3 structures (thyroid, left parotid, left nodes level II) was carried out. Performance metrics were calculated for thirteen HN structures to evaluate the auto-contours including dice similarity coefficient (DSC), 95th percentile Hausdorff distance (95HD) and mean surface distance (MSD). Results: We observed a high rate of low scores for PEI80-DD and VMI40 auto-segmentations on the thyroid and for GT and VMI40 contours on the nodes level II. All images received excellent scores for the parotid glands. The metrics comparison between GT and auto-segmented contours revealed that PEI80-DD had the highest DSC scores, significantly outperforming other reconstructed images for all organs (p < 0.05). Conclusions: The results indicate that the auto-contouring system cannot generalize to images derived from DECT acquisition. It is therefore crucial to identify which organs benefit from these acquisitions to adapt the training datasets accordingly.

Indexed as

Automatic segmentationDual-Energy Computed TomographyHead-and-neck cancerMulti-organ segmentationVirtual monoenergetic images

Identifiers

PMID39803347
PMCPMC11718415

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.