Evidence map›Paper›PMID 39801869›Full record

ArticleJournal of orthopaedic case reports2025

Revisiting Tension Band Principle Using Fiber Tape in Patella Fractures in Terms of Functional Outcomes, Complications, and Resurgery.

Sandeep Deore, Bhushan Patil, Nrupam Mehta, Sachin Kale, Ravi Modi, Rafiuddin Shaikh

Abstract read
In one paragraph

Article in Journal of orthopaedic case reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sandeep DeoreDepartment of Orthopaedic Surgery, Dr. D Y Patil Hospital, Nerul, Navi Mumbai, Maharashtra, India.
Bhushan PatilDepartment of Orthopaedic Surgery, Dr. D Y Patil Hospital, Nerul, Navi Mumbai, Maharashtra, India.
Nrupam MehtaDepartment of Orthopaedic Surgery, Dr. D Y Patil Hospital, Nerul, Navi Mumbai, Maharashtra, India.
Sachin KaleDepartment of Orthopaedic Surgery, Dr. D Y Patil Hospital, Nerul, Navi Mumbai, Maharashtra, India.
Ravi ModiDepartment of Orthopaedic Surgery, Dr. D Y Patil Hospital, Nerul, Navi Mumbai, Maharashtra, India.
Rafiuddin ShaikhDepartment of Orthopaedic Surgery, Dr. D Y Patil Hospital, Nerul, Navi Mumbai, Maharashtra, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Post-operative complications related to hardware, particularly symptoms caused by it, such as implant impingement, wire breakage, and skin infection are frequently reported following surgical management of patellar fractures with stainless steel wires. As a potential solution, some researchers have advocated for the use of non-absorbable sutures for fracture fixation. This study aims to investigate the clinical and radiological outcomes of patients treated with fiber taping as an alternative technique. Materials and Methods: We conducted a retrospective evaluation of 20 patients diagnosed radiographically with displaced patellar fractures (including transverse, poles, and severely comminuted). These patients underwent tension band technique with the help of high strength polyethylene fiber tape. Clinical and radiological outcomes were meticulously assessed, with specific attention to union time, complications, and functional outcome assessed by the Lysoholm scoring system, all of which were carefully observed and documented. Results: The mean age of the patients was 42.5 ± 14.3 years, and the majority were male (70%). The mean operative time was 68.5 ± 22.4 min. All fractures achieved union without any reported cases of wound complications, infections, loss of reduction, or implant failure. The mean Lysholm Knee Score improved from 36.4 ± 8.2 at baseline to 92.1 ± 5.9 at 12-month post-surgery. The visual analogue scale for pain decreased from 7.8 ± 1.4 at baseline to 0.8 ± 0.6 at 12 months. The mean range of motion improved from 96.5° ± 12.8° of flexion and -5.2° ± 3.1° of extension at baseline to 134.2° ± 6.1° of flexion and 0.6° ± 0.7° of extension at 12 months. Conclusion: Our investigation into a modified tension band technique using fiber tape sutures revealed encouraging clinical outcomes, marked by minimal complications. The adoption of fiber tape as a substitute for metal wire counterparts in patellar fracture treatment shows potential for reducing hardware related symptoms and shows lesser morbidity.

Indexed as

Fiber tapepatellar fracturestainless-steel wiretension band technique

Identifiers

PMID39801869
PMCPMC11723762

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.