Evidence map›Paper›PMID 39797996›Full record

ArticleMedical & biological engineering & computing2026

Automatic 4D mitral valve segmentation from transesophageal echocardiography: a semi-supervised learning approach.

Riccardo Munafò, Simone Saitta, Davide Tondi, Giacomo Ingallina, Paolo Denti, Francesco Maisano, Eustachio Agricola, Emiliano Votta

Registry-linked trialAbstract read
In one paragraph

Article in Medical & biological engineering & computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04787757 (Autonomous Robotics for Transcatheter dEliveRy sYstems), which is not on this map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04787757 completednot on this map

Autonomous Robotics for Transcatheter dEliveRy sYstems

TypeobservationalSponsorUniversità Vita-Salute San RaffaeleRan2021 to 2024Enrolled401ConditionsMitral Valve Disease, Heart Valve Diseases, Structural Heart AbnormalityArmsPercutaneous cardiac procedure
3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Riccardo MunafòDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy. riccardo.munafo@polimi.it.ORCID http://orcid.org/0000-0002-5624-2776
Simone SaittaDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.ORCID http://orcid.org/0000-0002-3974-5945
Davide TondiDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.ORCID http://orcid.org/0009-0009-8038-5476
Giacomo IngallinaUnit of Cardiovascular Imaging, IRCCS San Raffaele Hospital, Milan, Italy.ORCID http://orcid.org/0000-0002-4102-6405
Paolo DentiCardiac Surgery Department, IRCCS San Raffaele Hospital, Milan, Italy.ORCID http://orcid.org/0000-0002-3075-0203
Francesco MaisanoCardiac Surgery Department, IRCCS San Raffaele Hospital, Milan, Italy.ORCID http://orcid.org/0000-0002-3691-1709
Eustachio AgricolaUnit of Cardiovascular Imaging, IRCCS San Raffaele Hospital, Milan, Italy.ORCID http://orcid.org/0000-0002-4834-2187
Emiliano VottaDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.ORCID http://orcid.org/0000-0001-7115-0151

Funding

Horizon 2020 Framework Programme 101017140
6 · The paper itself

Abstract

Performing automatic and standardized 4D TEE segmentation and mitral valve analysis is challenging due to the limitations of echocardiography and the scarcity of manually annotated 4D images. This work proposes a semi-supervised training strategy using pseudo labelling for MV segmentation in 4D TEE; it employs a Teacher-Student framework to ensure reliable pseudo-label generation. 120 4D TEE recordings from 60 candidates for MV repair are used. The Teacher model, an ensemble of three convolutional neural networks, is trained on end-systole and end-diastole frames and is used to generate MV pseudo-segmentations on intermediate frames of the cardiac cycle. The pseudo-annotated frames augment the Student model's training set, improving segmentation accuracy and temporal consistency. The Student outperforms individual Teachers, achieving a Dice score of 0.82, an average surface distance of 0.37 mm, and a 95% Hausdorff distance of 1.72 mm for MV leaflets. The Student model demonstrates reliable frame-by-frame MV segmentation, accurately capturing leaflet morphology and dynamics throughout the cardiac cycle, with a significant reduction in inference time compared to the ensemble. This approach greatly reduces manual annotation workload and ensures reliable, repeatable, and time-efficient MV analysis. Our method holds strong potential to enhance the precision and efficiency of MV diagnostics and treatment planning in clinical settings.

Indexed as

Echocardiography, Four-DimensionalEchocardiography, TransesophagealImage Processing, Computer-AssistedMitral ValveSupervised Machine LearningConvolutional Neural NetworksHumansAutomatic segmentationConvolutional neural networkMitral regurgitationMitral valveSemi-supervised learningThree-dimensional transesophageal echocardiography

Identifiers

PMID39797996
PMCPMC13633368

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials