Evidence map›Paper›PMID 39797026›Full record

ArticleSensors (Basel, Switzerland)2025

An FPGA-Based SiNW-FET Biosensing System for Real-Time Viral Detection: Hardware Amplification and 1D CNN for Adaptive Noise Reduction.

Ahmed Hadded, Mossaad Ben Ayed, Shaya A Alshaya

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Ahmed HaddedComputer and Embedded System Laboratory, National Engineering School of Sfax, Sfax University, Sfax 3038, Tunisia.
Mossaad Ben AyedComputer and Embedded System Laboratory, National Engineering School of Sfax, Sfax University, Sfax 3038, Tunisia.ORCID 0000-0002-0350-2765
Shaya A AlshayaDepartment of Computer Science, Faculty of Sciences and Humanities Sciences, Majmaah University, Al Majmaah 11952, Saudi Arabia.ORCID 0000-0002-9169-1673

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Impedance-based biosensing has emerged as a critical technology for high-sensitivity biomolecular detection, yet traditional approaches often rely on bulky, costly impedance analyzers, limiting their portability and usability in point-of-care applications. Addressing these limitations, this paper proposes an advanced biosensing system integrating a Silicon Nanowire Field-Effect Transistor (SiNW-FET) biosensor with a high-gain amplification circuit and a 1D Convolutional Neural Network (CNN) implemented on FPGA hardware. This attempt combines SiNW-FET biosensing technology with FPGA-implemented deep learning noise reduction, creating a compact system capable of real-time viral detection with minimal computational latency. The integration of a 1D CNN model on FPGA hardware for adaptive, non-linear noise filtering sets this design apart from conventional filtering approaches by achieving high accuracy and low power consumption in a portable format. This integration of SiNW-FET with FPGA-based CNN noise reduction offers a unique approach, as prior noise reduction techniques for biosensors typically rely on linear filtering or digital smoothing, which lack adaptive capabilities for complex, non-linear noise patterns. By introducing the 1D CNN on FPGA, this architecture enables real-time, high-fidelity noise reduction, preserving critical signal characteristics without compromising processing speed. Notably, the findings presented in this work are based exclusively on comprehensive simulations using COMSOL and MATLAB, as no physical prototypes or biomarker detection experiments were conducted. The SiNW-FET biosensor, functionalized with antibodies specific to viral antigens, detects impedance shifts caused by antibody-antigen interactions, providing a highly sensitive platform for viral detection. A high-gain folded-cascade amplifier enhances the Signal-to-Noise Ratio (SNR) to approximately 70 dB, verified through COMSOL and MATLAB simulations. Additionally, a 1D CNN model is employed for adaptive noise reduction, filtering out non-linear noise patterns and achieving an approximate 75% noise reduction across a broad frequency range. The CNN model, implemented on an Altera DE2 FPGA, enables high-throughput, low-latency signal processing, making the system viable for real-time applications. Performance evaluations confirmed the proposed system's capability to enhance the SNR significantly while maintaining a compact and energy-efficient design suitable for portable diagnostics. This integrated architecture thus provides a powerful solution for high-precision, real-time viral detection, and continuous health monitoring, advancing the role of biosensors in accessible point-of-care diagnostics.

Indexed as

Biosensing TechniquesNeural Networks, ComputerVirusesDeep LearningHumansNanowiresSignal-To-Noise RatioSiliconTransistors, ElectronicSiliconFPGA-based 1D CNNimpedance-based sensingnoise reduction in biosensingreal-time viral detectionSiNW-FET biosensor

Identifiers

PMID39797026
PMCPMC11723262

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.