ArticleSensors (Basel, Switzerland)2024
Highly Responsive Robotic Prosthetic Hand Control Considering Electrodynamic Delay.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Emergent technologies in clinical neurophysiology to study the neuromuscular system: IFCN handbook chapter.Clinical neurophysiology practice · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
As robots become increasingly integrated into human society, the importance of human-machine interfaces continues to grow. This study proposes a faster and more accurate control system for myoelectric prostheses by considering the Electromechanical Delay (EMD), a key characteristic of Electromyography (EMG) signals. Previous studies have focused on systems designed for wrist movements without attempting implementation. To overcome this, we expanded the system's capability to handle more complex movements, such as those of fingers, by replacing the existing four-channel wired EMG sensor with an eight-channel wireless EMG sensor. This replacement improved the number of channels and user convenience. Additionally, we analyzed the communication delay introduced by this change and validated the feasibility of utilizing EMD. Furthermore, to address the limitations of the SISO-NARX model, we proposed a MISO-NARX model. To resolve issues related to model complexity and reduced accuracy due to the increased number of EMG channels, we introduced ridge regression, improving the system identification accuracy. Finally, we applied the ZPETC+PID controller to an actual servo motor and verified its performance. The results showed that the system reached the target value approximately 0.240 s faster than the response time of 0.428 s without the controller. This study significantly enhances the responsiveness and accuracy of myoelectric prostheses and is expected to contribute to the development of practical devices in the future.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.