Evidence map›Paper›PMID 39796898›Full record

ArticleSensors (Basel, Switzerland)2024

Automatic Optical Path Alignment Method for Optical Biological Microscope.

Guojin Peng, Zhenming Yu, Xinjian Zhou, Guangyao Pang, Kuikui Wang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Guojin PengKey Laboratory of Cognitive Radio and Information Processing, Ministry of Education, Guilin University of Electronic Technology, Guilin 541004, China.ORCID 0000-0002-9389-7704
Zhenming YuGuangxi Key Laboratory of Machine Vision and Intelligent Control, Wuzhou University, Wuzhou 543000, China.
Xinjian ZhouGuangxi Key Laboratory of Machine Vision and Intelligent Control, Wuzhou University, Wuzhou 543000, China.
Guangyao PangGuangxi Key Laboratory of Machine Vision and Intelligent Control, Wuzhou University, Wuzhou 543000, China.ORCID 0000-0001-8412-2547
Kuikui WangGuangxi Key Laboratory of Machine Vision and Intelligent Control, Wuzhou University, Wuzhou 543000, China.

Funding

Funding Scheme for Innovation and Technology Promotion of FDCT Grant Nos. 0009/2024/ITP1Innovation Project of Guangxi Graduate Education YCBZ2022110National Natural Science Foundation of China Grant Nos. 62262059the Key Laboratory of Cognitive Radio and Information Processing, Ministry of Education CRKL230202the University-Level Scientific Research Project of Wuzhou University 2022B017
6 · The paper itself

Abstract

A high-quality optical path alignment is essential for achieving superior image quality in optical biological microscope (OBM) systems. The traditional automatic alignment methods for OBMs rely heavily on complex masker-detection techniques. This paper introduces an innovative, image-sensor-based optical path alignment approach designed for low-power objective (specifically 4×) automatic OBMs. The proposed method encompasses reference objective (RO) identification and alignment processes. For identification, a model depicting spot movement with objective rotation near the optical axis is developed, elucidating the influence of optical path parameters on spot characteristics. This insight leads to the proposal of an RO identification method utilizing an edge gradient and edge position probability. In the alignment phase, a symmetry-based weight distribution scheme for concentric arcs is introduced. A significant observation is that the received energy stabilizes with improved alignment precision, prompting the design of an advanced alignment evaluation method that surpasses conventional energy-based assessments. The experimental results confirm that the proposed RO identification method can effectively differentiate between 4× and 10× objectives across diverse light intensities and exposure levels, with a significant numerical difference of up to 100. The error-radius ratio of the weighted circular fitting method is maintained below 1.16%, and the fine alignment stage's evaluation curve is notably sharper. Moreover, tests under various imaging conditions in artificially saturated environments indicate that the alignment estimation method, predicated on critical saturation positions, achieves an average error of 0.875 pixels.

Indexed as

Image Processing, Computer-AssistedMicroscopyAlgorithmsHumansalignment evaluationbiological microscopeobjective identificationoptical path alignmentweighted circle fitting

Identifiers

PMID39796898
PMCPMC11723072

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked