ArticleSensors (Basel, Switzerland)2024
A Novel Real-Time Threshold Algorithm for Closed-Loop Epilepsy Detection and Stimulation System.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Real-Time Multi-Channel Epileptic Seizure Detection Exploiting an Ultra-Low-Complexity Algorithm-Hardware Co-Design Approach.Sensors (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
Abstract
Epilepsy, as a common brain disease, causes great pain and stress to patients around the world. At present, the main treatment methods are drug, surgical, and electrical stimulation therapies. Electrical stimulation has recently emerged as an alternative treatment for reducing symptomatic seizures. This study proposes a novel closed-loop epilepsy detection system and stimulation control chip. A time-domain detection algorithm based on amplitude, slope, line length, and signal energy characteristics is introduced. A new threshold calculation method is proposed; that is, the threshold is updated by means of the mean and standard deviation of four consecutive eigenvalues through parameter combination. Once a seizure is detected, the system begins to control the stimulation of a two-phase pulse current with an amplitude and frequency of 34 μA and 200 Hz, respectively. The system is physically designed on the basis of the UMC 55 nm process and verified by a field programmable gate array verification board. This research is conducted through innovative algorithms to reduce power consumption and the area of the circuit. It can maintain a high accuracy of more than 90% and perform seizure detection every 64 ms. It is expected to provide a new treatment for patients with epilepsy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.