Evidence map›Paper›PMID 39795521›Full record

ArticlePolymers2025

A 3D-Printed Aqueous Drainage Tube with an Expandable Inner Diameter to Accommodate the Intraocular Pressure (IOP) Fluctuations After Glaucoma Surgery.

Jae-Seok Kim, Hun-Jin Jeong, Ji-Woo Park, So-Jung Gwak, Jeong-Sun Han, Kyoung In Jung, Seung-Jae Lee

Abstract read
In one paragraph

Article in Polymers, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jae-Seok KimDepartment of Mechanical Engineering, Wonkwang University, 460 Iksandae-ro, Iksan 54538, Republic of Korea.
Hun-Jin JeongRegenerative Engineering Laboratory, Columbia University, 630W 168th ST, New York, NY 10032, USA.ORCID 0000-0002-9756-0498
Ji-Woo ParkDepartment of Chemical Engineering, Wonkwang University, 460 Iksandae-ro, Iksan 54538, Republic of Korea.
So-Jung GwakDepartment of Chemical Engineering, Wonkwang University, 460 Iksandae-ro, Iksan 54538, Republic of Korea.
Jeong-Sun HanDepartment of Ophthalmology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.ORCID 0000-0002-4491-626X
Kyoung In JungDepartment of Ophthalmology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.
Seung-Jae LeeDepartment of Mechanical Engineering, Wonkwang University, 460 Iksandae-ro, Iksan 54538, Republic of Korea.

Funding

Institute of Civil-Military Technology Cooperation 22-CM-BR-12National Research Foundation of Korea 2022R1A2C2008149National Research Foundation of Korea 2023RIS-008
6 · The paper itself

Abstract

Glaucoma treatment involves reducing the intraocular pressure (IOP), which can damage the optic nerve, to a normal range. Aqueous drainage devices may be used for treatment, and a variety of devices have been proposed. However, they have a non-variable and uniform inner diameter, which makes it difficult to accommodate the IOP fluctuations that occur after glaucoma surgery. To ensure effective treatment in the early post-operative period with low IOP and the late post-operative period with high IOP, the inner diameter should be expandable over time to allow for smooth aqueous drainage. Here, we applied 3D printing technology with a tri-axial nozzle to develop an aqueous drainage tube that can expand its inner diameter. The distinct bilayer structure of the device allows it to expand its inner diameter through biodegradation, which can accommodate the IOP fluctuations that often occur after glaucoma surgery. The fabricated structure was evaluated in a series of tests, including leakage, cytotoxicity, and degradation experiments. The device did not show any leakage, was not toxic to cells, and demonstrated the expansion of the inner diameter through biodegradation. The device may provide a more effective post-operative solution for glaucoma patients by alleviating the effects of low IOP in the early post-operative period and high IOP in the late post-operative period.

Indexed as

3D printingaqueous drainage tubebiodegradationglaucomatri-axial nozzle

Identifiers

PMID39795521
PMCPMC11722927

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.