Evidence map›Paper›PMID 39794777›Full record

ArticleHead & face medicine2025

Novel CAD/CAM-splint-based navigation protocol enhances intraoperative maxillary position control in orthognathic surgery: a case control study.

Felix Schrader, Leonardo Saigo, Norbert Kübler, Majeed Rana, Max Wilkat

Abstract read
In one paragraph

Article in Head & face medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Felix SchraderDepartment of Oral and Maxillofacial Surgery, Heinrich Heine University Hospital Düsseldorf, Moorenstraße 5, 40225, Düsseldorf, Germany.
Leonardo SaigoDepartment of Oral and Maxillofacial Surgery, National Dental Centre Singapore, 5 Second Hospital Ave, Singapore, 168938, Singapore.
Norbert KüblerDepartment of Oral and Maxillofacial Surgery, Heinrich Heine University Hospital Düsseldorf, Moorenstraße 5, 40225, Düsseldorf, Germany.
Majeed RanaDepartment of Oral and Maxillofacial Surgery, Heinrich Heine University Hospital Düsseldorf, Moorenstraße 5, 40225, Düsseldorf, Germany.
Max WilkatDepartment of Oral and Maxillofacial Surgery, Heinrich Heine University Hospital Düsseldorf, Moorenstraße 5, 40225, Düsseldorf, Germany. Max.Wilkat@med.uni-duesseldorf.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundVirtual surgical planning for orthognathic surgery typically relies on two methods for intraoperative plan transfer: CAD/CAM occlusal splints and patient-specific implants (PSI). While CAD/CAM splints may offer limited accuracy, particularly in the vertical dimension, PSIs are constrained by higher costs and extended preparation times. Surgical navigation has emerged as a potential alternative, but existing protocols often involve invasive registration or lack transparent evaluation. This study introduces a novel protocol for point-based optical navigation using modified CAD/CAM splints for non-invasive registration and transparent intraoperative evaluation, assessing its effectiveness in maxillary positioning.

methodsThis prospective case-control study included 20 patients undergoing bimaxillary orthognathic surgery. The experimental group employed surgical navigation with modified CAD/CAM splints, while the control group used standard CAD/CAM splints. Surgical accuracy was evaluated by measuring translational and rotational discrepancies between the planned and achieved maxillary positions. A mixed ANOVA was conducted to assess other factors, aside from surgical navigation, that might influence surgical accuracy.

resultsSurgical navigation significantly improved accuracy in translational movements along the x-axis (right-left: -0.81 mm; p = 0.021) and z-axis (down-up: -0.82 mm; p = 0.014), as well as in yaw rotation (-0.45°; p = 0.045). Other movements also showed improved precision in the navigated group, though not statistically significant; y-axis (back-front): -0.60 mm (p = 0.094); pitch rotation: -0.70° (p = 0.071); roll rotation: -0.04° (p = 0.428). Besides the use of surgical navigation, the amount of planned movement significantly impacted surgical accuracy, although no specific factors could be identified to predict which cases would particularly benefit from surgical navigation.

conclusionsSurgical navigation with modified CAD/CAM splints enhances surgical accuracy without requiring invasive procedures, offering a straightforward and transparent protocol suitable for routine clinical practice that allows intraoperative evaluation of maxillary positioning. However, the clinical significance and cost-effectiveness compared to PSI need further investigation. These findings suggest new directions for future developments, especially with advancements in mixed reality technologies, which could broaden the application of surgical navigation.

trial registrationRetrospectively registered with the German Clinical Trials Register (DRKS00034795).

Indexed as

Computer-Aided DesignMaxillaOcclusal SplintsOrthognathic Surgical ProceduresSurgery, Computer-AssistedAdultCase-Control StudiesFemaleHumansMaleProspective StudiesYoung AdultCAD/CAM splintComputer-assisted planningIntra-oral scanningNavigational registrationOrthognathic surgerySurgical navigation

Identifiers

PMID39794777
PMCPMC11721267

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.