ArticleOptometry and vision science : official publication of the American Academy of Optometry2025
Internal validation of a convolutional neural network pipeline for assessing meibomian gland structure from meibography.
Article in Optometry and vision science : official publication of the American Academy of Optometry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- A Comprehensive Review Comparing Artificial Intelligence and Clinical Diagnostic Approaches for Dry Eye Disease.Diagnostics (Basel, Switzerland) · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
significanceOptimal meibography utilization and interpretation are hindered due to poor lid presentation, blurry images, or image artifacts and the challenges of applying clinical grading scales. These results, using the largest image dataset analyzed to date, demonstrate development of algorithms that provide standardized, real-time inference that addresses all of these limitations. PURPOSE: This study aimed to develop and validate an algorithmic pipeline to automate and standardize meibomian gland absence assessment and interpretation.
methodsA total of 143,476 images were collected from sites across North America. Ophthalmologist and optometrist experts established ground-truth image quality and quantification (i.e., degree of gland absence). Annotated images were allocated into training, validation, and test sets. Convolutional neural networks within Google Cloud VertexAI trained three locally deployable or edge-based predictive models: image quality detection, over-flip detection, and gland absence detection. The algorithms were combined into an algorithmic pipeline onboard a LipiScan Dynamic Meibomian Imager to provide real-time clinical inference for new images. Performance metrics were generated for each algorithm in the pipeline onboard the LipiScan from naive image test sets.
resultsIndividual model performance metrics included the following: weighted average precision (image quality detection: 0.81, over-flip detection: 0.88, gland absence detection: 0.84), weighted average recall (image quality detection: 0.80, over-flip detection: 0.87, gland absence detection: 0.80), weighted average F1 score (image quality detection: 0.80, over-flip detection: 0.87, gland absence detection: 0.81), overall accuracy (image quality detection: 0.80, over-flip detection: 0.87, gland absence detection: 0.80), Cohen κ (image quality detection: 0.60, over-flip detection: 0.62, and gland absence detection: 0.71), Kendall τb (image quality detection: 0.61, p<0.001, over-flip detection: 0.63, p<0.001, and gland absence detection: 0.67, p<001), and Matthews coefficient (image quality detection: 0.61, over-flip detection: 0.63, and gland absence detection: 0.62). Area under the precision-recall curve (image quality detection: 0.87 over-flip detection: 0.92, gland absence detection: 0.89) and area under the receiver operating characteristic curve (image quality detection: 0.88, over-flip detection: 0.91 gland absence detection: 0.93) were calculated across a common set of thresholds, ranging from 0 to 1.
conclusionsComparison of predictions from each model to expert panel ground-truth demonstrated strong association and moderate to substantial agreement. The findings and performance metrics show that the pipeline of algorithms provides standardized, real-time inference/prediction of meibomian gland absence.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.