Evidence map›Paper›PMID 39792214›Full record

ArticleInsights into imaging2025

Fluoroscopy-guided aspiration of the acutely dislocated total hip arthroplasty: a feasible, high-yield, and safe procedure.

Dyan V Flores, Abdullah Felemban, Taryn Hodgdon, Paul Beaulé, George Grammatopoulos, Kawan S Rakhra

Erratum issuedAbstract read
In one paragraph

Article in Insights into imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Dyan V FloresDepartment of Radiology, Radiation Oncology and Medical Physics Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada.
Abdullah FelembanDepartment of Radiology, King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia.
Taryn HodgdonDepartment of Radiology, Radiation Oncology and Medical Physics Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada.
Paul BeauléOttawa Hospital Research Institute, Ottawa, ON, Canada.
George GrammatopoulosOttawa Hospital Research Institute, Ottawa, ON, Canada.
Kawan S RakhraDepartment of Radiology, Radiation Oncology and Medical Physics Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada. krakhra@toh.ca.ORCID http://orcid.org/0000-0002-1787-9096

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo determine the feasibility, yield, and safety of fluoroscopic-guided aspiration of the acutely dislocated total hip arthroplasty (AD-THA). MATERIALS AND

methodsIRB-approved, retrospective review of fluoroscopic-guided aspirations of AD-THA (January 2005-December 2023) was performed. Data from electronic charts and fluoroscopy images/reports were obtained. Positive yield was defined as spontaneous aspirate or saline rinse adequate for microbiology analysis. Sub-analysis by needle target (acetabular cup or femur) was performed for spontaneous aspiration rate, aspirate volume and fluoroscopy time. Differences between groups were analyzed with unpaired, t-test (2-tail) and between proportions with Fisher's exact test, with significance p < 0.05.

resultsAspiration of 20 AD-THA in 19 patients (12 female, mean age (SD) of 73 years (16)) targeted the acetabular cup in 45% (9/20) or femur in 55% (11/20) of cases. Positive yield was obtained in 95% (19/20), with spontaneous aspirate in 75% (15/20) and saline rinse in 20% (4/20) of cases; in 5% (1/20), no diagnostic sample was obtained. Spontaneous aspirate mean volume (SD, range) for all cases was 8.3 mL (6.9, 0.2-25), and higher when targeting the acetabular cup 11.2 mL (6.9, 5-25) versus the femur 4.0 mL (4.4, 0.2-12) (p = 0.026). The rate of spontaneous aspiration was higher for the acetabular cup 100% (9/9) versus the femur 55% (6/11) (p = 0.038). The mean fluoroscopy time (SD, range) for all cases was 43 s (25, 19-102), and shorter for targeting the acetabular cup 32 s (16, 19-75) versus the femur 56 s (28, 28-102) (p = 0.034). No immediate complications occurred in all aspirations.

conclusionFluoroscopy-guided aspiration of AD-THA is a feasible, high-yield, and safe procedure. Targeting the acetabular cup results in a higher rate of spontaneous aspirate, larger aspiration volume, and lower fluoroscopy time. CRITICAL RELEVANCE STATEMENT: Although technically more challenging, radiologists should feel confident aspirating the acutely dislocated total hip arthroplasty (AD-THA) under fluoroscopic guidance. KEY POINTS: Total hip arthroplasty (THA) infection can be evaluated with synovial fluid aspiration. Fluoroscopic-guided aspiration of the dislocated THA is feasible, high-yield, and safe. Targeting of the acetabular cup is recommended over the femoral prosthetic component. Acetabular cup targeting gives larger, spontaneous aspirates with lower fluoroscopy time.

Indexed as

DislocationFluoroscopyImage-guided hip aspirationInterventionTotal hip arthroplasty

Identifiers

PMID39792214
PMCPMC11723859

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.