Evidence map›Paper›PMID 39789790›Full record

ArticleJMIR mHealth and uHealth2025

Reliability and Accuracy of the Fitbit Charge 4 Photoplethysmography Heart Rate Sensor in Ecological Conditions: Validation Study.

Maxime Ceugniez, Hervé Devanne, Eric Hermand

Abstract read
In one paragraph

Article in JMIR mHealth and uHealth, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Maxime CeugniezULR 7369 - URePSSS - Unité de Recherche Pluridisciplinaire Sport Santé Société, Univ. Littoral Côte d'Opale, Univ. Lille, Univ. Artois, 189b, Avenue Maurice Schumann, Centre Universitaire des Darses, Dunkerque, 59375, France, 33 328237357.ORCID 0009-0004-3655-3114
Hervé DevanneULR 7369 - URePSSS - Unité de Recherche Pluridisciplinaire Sport Santé Société, Univ. Littoral Côte d'Opale, Univ. Lille, Univ. Artois, 189b, Avenue Maurice Schumann, Centre Universitaire des Darses, Dunkerque, 59375, France, 33 328237357.ORCID 0000-0002-0296-9152
Eric HermandULR 7369 - URePSSS - Unité de Recherche Pluridisciplinaire Sport Santé Société, Univ. Littoral Côte d'Opale, Univ. Lille, Univ. Artois, 189b, Avenue Maurice Schumann, Centre Universitaire des Darses, Dunkerque, 59375, France, 33 328237357.ORCID 0000-0002-3925-3393

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Wrist-worn photoplethysmography (PPG) sensors allow for continuous heart rate (HR) measurement without the inconveniences of wearing a chest belt. Although green light PPG technology reduces HR measurement motion artifacts, only a limited number of studies have investigated the reliability and accuracy of wearables in non-laboratory-controlled conditions with actual specific and various physical activity movements. Objective: The purpose of this study was to (1) assess the reliability and accuracy of the PPG-based HR sensor of the Fitbit Charge 4 (FC4) in ecological conditions and (2) quantify the potential variability caused by the nature of activities. Methods: We collected HR data from participants who performed badminton, tennis, orienteering running, running, cycling, and soccer while simultaneously wearing the FC4 and the Polar H10 chest belt (criterion sensor). Skin tone was assessed with the Fitzpatrick Skin Scale. Once data from the FC4 and criterion data were synchronized, accuracy and reliability analyses were performed, using intraclass correlation coefficients (ICCs), Lin concordance correlation coefficients (CCCs), mean absolute percentage errors (MAPEs), and Bland-Altman tests. A linear univariate model was also used to evaluate the effect of skin tone on bias. All analyses were stratified by activity and pooled activity types (racket sports and running sports). Results: A total of 77.5 hours of HR recordings from 26 participants (age: mean 21.1, SD 5.8 years) were analyzed. The highest reliability was found for running sports, with ICCs and CCCs of 0.90 and 0.99 for running and 0.80 and 0.93 for orienteering running, respectively, whereas the ICCs and CCCs were 0.37 and 0.78, 0.42 and 0.88, 0.65 and 0.97, and 0.49 and 0.81 for badminton, tennis, cycling, and soccer, respectively. We found the highest accuracy for running (bias: 0.1 beats per minute [bpm]; MAPE 1.2%, SD 4.6%) and the lowest for badminton (bias: -16.5 bpm; MAPE 16.2%, SD 14.4%) and soccer (bias: -16.5 bpm; MAPE 17.5%, SD 20.8%). Limit of agreement (LOA) width and artifact rate followed the same trend. No effect of skin tone was observed on bias. Conclusions: LOA width, bias, and MAPE results found for racket sports and soccer suggest a high sensitivity to motion artifacts for activities that involve "sharp" and random arm movements. In this study, we did not measure arm motion, which limits our results. However, whereas individuals might benefit from using the FC4 for casual training in aerobic sports, we cannot recommend the use of the FC4 for specific purposes requiring high reliability and accuracy, such as research purposes.

Indexed as

Heart RatePhotoplethysmographyAdultFemaleHumansMaleReproducibility of ResultsWearable Electronic Devicesaccuracydeviceecologicalecological conditionsexerciseFitbitFitbit Charge 4heart rateheart rate sensorphotoplethysmographyphysical activityreliabilitysensitivitysensorusefulnessvariabilitywearableswrist-worn device

Identifiers

PMID39789790
PMCPMC11735015

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.