Evidence map›Paper›PMID 39780240›Full record

ArticleJournal of orthopaedic surgery and research2025

Diagnostic efficacy of dual-energy CT virtual non-calcium technique in the diagnosis of bone marrow edema of sacroiliac joints in ankylosing spondylitis.

Hongyue Lu, Zhi Li, Ziheng Liang, Yuqi Liu

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Hongyue LuMedical school, Kunming University of Science and Technology, Kunming, Yunnan, China.
Zhi LiDepartment of Radiology, The First People's Hospital of Yunnan Province, Kunming, Yunnan, China. qqli7716@sina.com.
Ziheng LiangMedical school, Kunming University of Science and Technology, Kunming, Yunnan, China.
Yuqi LiuMedical school, Kunming University of Science and Technology, Kunming, Yunnan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveIn-depth investigation of the diagnostic performance of dual-energy CT (DECT) virtual non-calcium (VNCa) technique for sacroiliac joint bone marrow edema (BME) in patients with ankylosing spondylitis(AS).

methodsA total of 42 patients with AS)who underwent sacroiliac joint MRI and DECT scans on the same day at our Rheumatology and Immunology Department between August 2022 and June 2023 were selected. Using MRI as the reference standard, the presence of BME on the iliac and sacral surfaces was evaluated, resulting in the categorization of patients into BME-positive and BME-negative groups. Subsequently, the DECT scan data was processed using the "Bone Marrow" algorithm to generate VNCa color-coded images of the bone marrow. The diagnostic performance of DECT in detecting BME was assessed through visual qualitative evaluation and objective quantitative analysis.

resultsVisual qualitative assessment analysis showed good agreement between the results of BME analysis on virtual non-calcium images and MRI images by both physicians (Kappa > 0.61). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of visual qualitative assessment for BME by Physicians A and B were as follows: iliac facet [(92.5%, 88.6%, 88.1%, 92.9%, 90.5%), (90.0%, 90.9%, 90.0%, 90.9%, 90.5%)], sacral facet [(88.4%, 87.8%, 88.4%, 87.8%, 88.1%), (90.7%, 85.3%, 86.7%, 89.7%, 88.1%)].In terms of objective quantitative analysis, the CT values of the edematous areas on the iliac and sacral surfaces were (-41.4 ± 15.9) Hu and (-38.8 ± 19.7) Hu, respectively, while the CT values of normal bone marrow areas were (-79.6 ± 18.2) Hu and (-72.8 ± 14.8) Hu, respectively. The CT values of the edematous areas were higher than those of the non-edematous areas. Based on the receiver operating characteristic curve analysis, the area under the curve for the iliac and sacral surfaces were 0.90 and 0.89, respectively. The optimal CT cutoff values were - 57.4 Hu and - 56.8 Hu, with corresponding sensitivities of 92.5% and 86.4% and specificities of 90.7% and 87.8%.

conclusionThe DECT VNCa technique has a high diagnostic efficacy in the diagnosis of BME in the sacroiliac joints in ankylosing spondylitis in terms of visual qualitative assessment and objective quantitative analysis.

Indexed as

Bone Marrow DiseasesEdemaMagnetic Resonance ImagingSacroiliac JointSpondylitis, AnkylosingTomography, X-Ray ComputedAdultBone MarrowFemaleHumansMaleMiddle AgedSensitivity and SpecificityYoung AdultAnkylosing spondylitisBone marrow edema of the sacroiliac jointsDECT VNCaDiagnostic efficacy

Identifiers

PMID39780240
PMCPMC11715202

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.