Evidence map›Paper›PMID 39779816›Full record

ArticleScientific reports2025

A super-resolution algorithm to fuse orthogonal CT volumes using OrthoFusion.

Rebecca E Abbott, Alain Nishimwe, Hadi Wiputra, Ryan E Breighner, Arin M Ellingson

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Rebecca E AbbottDivisions of Physical Therapy and Rehabilitation Science, Department of Family Medicine and Community Health, University of Minnesota, Minneapolis, MN, 55455, USA.
Alain NishimweDepartment of Biomedical Engineering, University of Minnesota, Minneapolis, MN, 55455, USA.
Hadi WiputraDepartment of Biomedical Engineering, University of Minnesota, Minneapolis, MN, 55455, USA.
Ryan E BreighnerDepartment of Radiology and Imaging, Hospital for Special Surgery, New York, NY, 10021, USA.
Arin M EllingsonDivisions of Physical Therapy and Rehabilitation Science, Department of Family Medicine and Community Health, University of Minnesota, Minneapolis, MN, 55455, USA. ellin224@umn.edu.

Funding

University of Minnesota Clinical and Translational Science Institute (UMN CTSI)UL1TR002494 · NCATS · UNIVERSITY OF MINNESOTA · PI BLAZAR, BRUCE R, WEISDORF, DANIEL J · 2018 to 2022
$34.9M
NRSA Training CoreTL1TR002493 · NCATS · UNIVERSITY OF MINNESOTA · PI FULKERSON, JAYNE ALLYN · 2018 to 2022
$3.1M
Generalized joint hypermobility and chronic neck pain: associations with dynamic cervical spine instabilityF32AR082276 · NIAMS · UNIVERSITY OF MINNESOTA · PI ABBOTT, REBECCA · 2023 to 2023
$39k
Minnesota Partnership for Biotechnology and Medical Genomics MHP IF #14.02NCATS NIH HHS TL1 TR002493NCATS NIH HHS UL1 TR002494NIAMS NIH HHS F32 AR082276NIH HHS R03HD09771NIH HHS TL1R002493
6 · The paper itself

Abstract

OrthoFusion, an intuitive super-resolution algorithm, is presented in this study to enhance the spatial resolution of clinical CT volumes. The efficacy of OrthoFusion is evaluated, relative to high-resolution CT volumes (ground truth), by assessing image volume and derived bone morphological similarity, as well as its performance in specific applications in 2D-3D registration tasks. Results demonstrate that OrthoFusion significantly reduced segmentation time, while improving structural similarity of bone images and relative accuracy of derived bone model geometries. Moreover, it proved beneficial in the context of biplane videoradiography, enhancing the similarity of digitally reconstructed radiographs to radiographic images and improving the accuracy of relative bony kinematics. OrthoFusion's simplicity, ease of implementation, and generalizability make it a valuable tool for researchers and clinicians seeking high spatial resolution from existing clinical CT data. This study opens new avenues for retrospectively utilizing clinical images for research and advanced clinical purposes, while reducing the need for additional scans, mitigating associated costs and radiation exposure.

Indexed as

AlgorithmsTomography, X-Ray ComputedBone and BonesHumansImage Processing, Computer-AssistedImaging, Three-DimensionalBone modelsComputed tomographyImage FusionSpatial resolution enhancementSuper Resolution

Identifiers

PMID39779816
PMCPMC11711182

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.