ArticleEuropean radiology2025
Repeatability of AI-based, automatic measurement of vertebral and cardiovascular imaging biomarkers in low-dose chest CT: the ImaLife cohort.
Article in European radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Artificial Intelligence in Cerebrovascular Disease Management: A Comprehensive Review of Risk Prediction, Diagnosis, Therapeutic Optimization, and Clinical Translation.Vascular health and risk management · 2025Pooled it
- Repeatability of AI-quantified incidental findings on lung cancer screening CT scans in the NELSON trial.European radiology · 2026Article
- Human-AI interaction and collaboration in radiology: from conceptual frameworks to responsible implementation.Diagnostic and interventional radiology (Ankara, Turkey) · 2026Review
- Emerging technologies in thoracic surgery: artificial intelligence, robotic-assisted surgery, and telesurgery.Frontiers in surgery · 2026Review
- The role of AI assistance in the evaluation of unenhanced chest CT scans in an emergency setting.Polish journal of radiology · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo evaluate the repeatability of AI-based automatic measurement of vertebral and cardiovascular markers on low-dose chest CT.
methodsWe included participants of the population-based Imaging in Lifelines (ImaLife) study with low-dose chest CT at baseline and 3-4 month follow-up. An AI system (AI-Rad Companion chest CT prototype) performed automatic segmentation and quantification of vertebral height and density, aortic diameters, heart volume (cardiac chambers plus pericardial fat), and coronary artery calcium volume (CACV). A trained researcher visually checked segmentation accuracy. We evaluated the repeatability of adequate AI-based measurements at baseline and repeat scan using Intraclass Correlation Coefficient (ICC), relative differences, and change in CACV risk categorization, assuming no physiological change.
resultsOverall, 632 participants (63 ± 11 years; 56.6% men) underwent short-term repeat CT (mean interval, 3.9 ± 1.8 months). Visual assessment showed adequate segmentation in both baseline and repeat scan for 98.7% of vertebral measurements, 80.1-99.4% of aortic measurements (except for the sinotubular junction (65.2%)), and 86.0% of CACV. For heart volume, 53.5% of segmentations were adequate at baseline and repeat scans. ICC for adequately segmented cases showed excellent agreement for all biomarkers (ICC > 0.9). Relative difference between baseline and repeat measurements was < 4% for vertebral and aortic measurements, 7.5% for heart volume, and 28.5% for CACV. There was high concordance in CACV risk categorization (81.2%).
conclusionIn low-dose chest CT, segmentation accuracy of AI-based software was high for vertebral, aortic, and CACV evaluation and relatively low for heart volume. There was excellent repeatability of vertebral and aortic measurements and high concordance in overall CACV risk categorization. KEY POINTS: Question Can AI algorithms for opportunistic screening in chest CT obtain an accurate and repeatable result when applied to multiple CT scans of the same participant? Findings Vertebral and aortic analysis showed accurate segmentation and excellent repeatability; coronary calcium segmentation was generally accurate but showed modest repeatability due to a non-electrocardiogram-triggered protocol. Clinical relevance Opportunistic screening for diseases outside the primary purpose of the CT scan is time-consuming. AI allows automated vertebral, aortic, and coronary artery calcium (CAC) assessment, with highly repeatable outcomes of vertebral and aortic biomarkers and high concordance in overall CAC categorization.
Indexed as