All Suture Biceps Tenodesis Has Greater Biomechanical Strength Than Metal Button Fixation.

Matthew J Kinnard, Jeremy D Tran, Steven D Voinier, Donald F Colantonio, Timothy P Murphy, Patrick K Mescher, Michael A Donohue, Melvin D Helgeson, Christopher J Tucker

Abstract read
In one paragraph

Article in Arthroscopy, sports medicine, and rehabilitation, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Matthew J KinnardDepartment of Orthopaedic Surgery, Walter Reed National Military Medical Center, Bethesda, Maryland, U.S.A.
Jeremy D TranDepartment of Orthopaedic Surgery, Walter Reed National Military Medical Center, Bethesda, Maryland, U.S.A.
Steven D VoinierDepartment of Orthopaedic Surgery, Walter Reed National Military Medical Center, Bethesda, Maryland, U.S.A.
Donald F ColantonioDepartment of Orthopaedic Surgery, Keller Army Community Hospital, West Point, New York, U.S.A.
Timothy P MurphyDepartment of Orthopaedic Surgery, Walter Reed National Military Medical Center, Bethesda, Maryland, U.S.A.
Patrick K MescherDepartment of Orthopaedic Surgery, Walter Reed National Military Medical Center, Bethesda, Maryland, U.S.A.
Michael A DonohueDepartment of Orthopaedic Surgery, Keller Army Community Hospital, West Point, New York, U.S.A.
Melvin D HelgesonDepartment of Orthopaedic Surgery, Walter Reed National Military Medical Center, Bethesda, Maryland, U.S.A.
Christopher J TuckerDepartment of Orthopaedic Surgery, Walter Reed National Military Medical Center, Bethesda, Maryland, U.S.A.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To evaluate the maximal load to failure, cyclic displacement, stiffness, and modes of failure of onlay subpectoral biceps tenodesis with an intramedullary unicortical metal button (MB) versus an inlay, all-suture Caspari-Weber (CW) technique. Methods: Sixteen matched paired human cadaveric proximal humeri were randomly allocated for subpectoral BT with either CW or MB using a high-strength suture (N = 16; 8 male, 8 female, mean age = 82.5 years, range 62-99 years). Specimens were tested on a servohydraulic mechanical testing apparatus under cyclic load for 1,000 cycles and then loaded to failure. Maximal load to failure, displacement, construct stiffness, and mode of failure were compared. Results: There was no significant difference between groups when comparing construct stiffness, creep displacement, or displacement at ultimate load. The maximal load to failure for the CW technique was greater than the unicortical MB (588.36 ± 149.06 N vs 375.83 ± 131.4 N, Conclusions: In this study, the all-suture CW biceps tenodesis technique had a greater maximal load to failure than the onlay unicortical MB technique while having similar construct displacement and stiffness. The CW subpectoral biceps tenodesis may offer a lower cost alternative with a mechanically robust fixation when performing an open subpectoral biceps tenodesis. Clinical Relevance: This cadaveric biomechanical study can help guide surgeons when selecting a fixation technique for biceps tenodesis.