ArticleArchives of orthopaedic and trauma surgery2025
Distal augmentation in unstable distal clavicle fractures: a retrospective cohort study of 101 cases.
Article in Archives of orthopaedic and trauma surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Comparative analysis of vertical double plate versus clavicle hook plate for unstable distal clavicle fractures.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThe optimal management strategy for unstable distal clavicular fractures remains controversial. Recent studies on plate techniques have reported good-to-excellent outcomes with no serious complications. The questions are that: (1) Does the use of wire augmentation with locking plate in distal part (distal wire augmentation) reduce radiographic loss of reduction (RLOR) and get earlier bony union in distal clavicular fractures? (2) Which fixation methods are associated with a higher incidence of acromioclavicular (AC) joints arthritis or subluxation? We collected and analyzed clinical studies on different plate fixation methods for unstable fractures to identify the best surgical modality.
methodsThis retrospective case-control study included 101 patients with Neer types IIB and V unstable distal clavicle fractures treated using plate techniques. The patients were divided into four groups according to the surgical procedure: hook plate (HP group) (n = 13), lateral locking plate alone (LP group) (n = 41), locking plate with coracoclavicular (CC) ligament suture repair (LPC group) (n = 26), and locking plate with distal wire augmentation (LPA group) without CC repair (n = 21). The clinical outcomes of shoulder function were the mean Constant score and the University of California-Los Angeles (UCLA) shoulder scale. The bony union time, loss of CC distance reduction, and AC joint condition were used to evaluate the radiographic results. One-way ANOVA, Kruskal-Wallis test, and chi-square test were performed to compare differences between groups. Multiple p-value comparison corrections were calculated using the Bonferroni method.
resultsThere were no significant differences in the mean Constant and UCLA scores among the groups after 1 year of follow-up. All fractures healed. The LPA and HP groups achieved earlier bone union (LPA 8.4 weeks, HP 8.9 weeks, LP 12.6 weeks, and LPC 13.4 weeks, P = 0.000); however, the HP group had the highest complication rate and required bone removal (LPA 4.0%, HP 23.1%, LP 0.0%, LPC 0.0%, P = 0.003). A low rate of RLOR was observed in the LPA group (LPA 9.5%, HP 23.1%, LP 22.0%, LPC 30.8%, P = 0.362). The incidence of AC joint subluxation was higher in the Neer type V group and was unrelated to surgical methods.
conclusionsHook plate and locking plate with distal wire augmentation in distal clavicle fractures result in an earlier time to bone union when compared with CC suture repair or non-CC suture repair techniques. However, HP may have the higher complication rate and require subsequent implant removal. The incorporation of distal wire augmentation appears to be beneficial in maintaining fracture reduction. In the future, larger prospective studies are needed to confirm these findings. LEVEL OF EVIDENCE: Level III, therapeutic study.
Indexed as
Identifiers
39776266What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.