Evidence map›Paper›PMID 39775319›Full record

ArticlePloS one2024

Cerebral compliance assessment from intracranial pressure waveform analysis: Is a positional shift-related increase in intracranial pressure predictable?

Donatien Legé, Pierre-Henri Murgat, Russell Chabanne, Kevin Lagarde, Clément Magand, Jean-François Payen, Marion Prud'homme, Yoann Launey, Laurent Gergelé

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Donatien LegéDISC Department, FEMTO-ST, Université de Franche-Comté, Besançon, France.ORCID 0009-0006-4884-3164
Pierre-Henri MurgatDepartment of Anesthesia and Intensive Care, University Hospital of Saint-Etienne, Saint-Etienne, France.
Russell ChabanneDepartment of Anaesthesia, Critical Care Medicine and Perioperative Medicine, University Hospital of Clermont-Ferrand, Clermont-Ferrand, France.
Kevin LagardeDepartment of Anesthesia and Critical Care, University of Grenoble Alpes, CHU Grenoble Alpes, Grenoble, France.ORCID 0009-0008-4869-866X
Clément MagandDepartment of Anesthesia and Intensive Care, University Hospital of Saint-Etienne, Saint-Etienne, France.
Jean-François PayenDepartment of Anesthesia and Critical Care, University of Grenoble Alpes, CHU Grenoble Alpes, Grenoble, France.
Marion Prud'hommeSophysa, Orsay, France.
Yoann LauneyDepartment of Anaesthesia, Critical Care Medicine and Perioperative Medicine, University Hospital of Rennes, Rennes, France.ORCID 0000-0001-9105-8862
Laurent GergeléDepartment of Intensive Care, Ramsay Générale de Santé, Hôpital privé de la Loire, Saint Etienne, France.ORCID 0000-0002-7283-6793

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Real-time monitoring of intracranial pressure (ICP) is a routine part of neurocritical care in the management of brain injury. While mainly used to detect episodes of intracranial hypertension, the ICP signal is also indicative of the volume-pressure relationship within the cerebrospinal system, often referred to as intracranial compliance (ICC). Several ICP signal descriptors have been proposed in the literature as surrogates of ICC, but the possibilities of combining these are still unexplored. In the present study, a rapid ICC assessment consisting of a 30-degree postural shift was performed on a cohort of 54 brain-injured patients. 73 ICP signal features were calculated over the 20 minutes prior to the ICC test. After a selection step, different combinations of these features were provided as inputs to classification models. The goal was to predict the level of induced ICP elevation, which was categorized into three classes: less than 7 mmHg ("good ICC"), between 7 and 10 mmHg ("medium ICC"), and more than 10 mmHg ("poor ICC"). A logistic regression model fed with a combination of 5 ICP signal features discriminated the "poor ICC" class with an area under the receiving operator curve (AUROC) of 0.80 (95%-CI: [0.73-0.87]). The overall one-versus-one classification task was achieved with an averaged AUROC of 0.72 (95%-CI: [0.61-0.83]). Adding more features to the input set and/or using nonlinear machine learning algorithms did not significantly improve classification performance. This study highlights the potential value of analyzing the ICP signal independently to extract information about ICC status. At the patient's bedside, such univariate signal analysis could be implemented without dependence on a specific setup.

Indexed as

Intracranial PressureAdultAgedBrain InjuriesFemaleHumansIntracranial HypertensionMaleMiddle AgedMonitoring, PhysiologicPosture

Identifiers

PMID39775319
PMCPMC11684684

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.