Evidence map›Paper›PMID 39771948›Full record

ArticleSensors (Basel, Switzerland)2024

Knowledge Reasoning- and Progressive Distillation-Integrated Detection of Electrical Construction Violations.

Bin Ma, Gang Liang, Yufei Rao, Wei Guo, Wenjie Zheng, Qianming Wang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Bin MaState Grid Henan Electric Power Company Electric Power Science Research Institute, Zhengzhou 450052, China.
Gang LiangState Grid Henan Electric Power Company Electric Power Science Research Institute, Zhengzhou 450052, China.
Yufei RaoState Grid Henan Electric Power Company Electric Power Science Research Institute, Zhengzhou 450052, China.
Wei GuoState Grid Henan Electric Power Company, Zhengzhou 450052, China.
Wenjie ZhengDepartment of Automation, North China Electric Power University, Baoding 071003, China.
Qianming WangDepartment of Automation, North China Electric Power University, Baoding 071003, China.

Funding

the Fundamental Research Funds for the Central Universities 2024MS136
6 · The paper itself

Abstract

To address the difficulty in detecting workers' violation behaviors in electric power construction scenarios, this paper proposes an innovative method that integrates knowledge reasoning and progressive multi-level distillation techniques. First, standards, norms, and guidelines in the field of electric power construction are collected to build a comprehensive knowledge graph, aiming to provide accurate knowledge representation and normative analysis. Then, the knowledge graph is combined with the object-detection model in the form of triplets, where detected objects and their interactions are represented as subject-predicate-object relationship. These triplets are embedded into the model using an adaptive connection network, which dynamically weights the relevance of external knowledge to enhance detection accuracy. Furthermore, to enhance the model's performance, the paper designs a progressive multi-level distillation strategy. On one hand, knowledge transfer is conducted at the object level, region level, and global level, significantly reducing the loss of contextual information during distillation. On the other hand, two teacher models of different scales are introduced, employing a two-stage distillation strategy where the advanced teacher guides the primary teacher in the first stage, and the primary teacher subsequently distills this knowledge to the student model in the second stage, effectively bridging the scale differences between the teacher and student models. Experimental results demonstrate that under the proposed method, the model size is reduced from 14.5 MB to 3.8 MB, and the floating-point operations (FLOPs) are reduced from 15.8 GFLOPs to 5.9 GFLOPs. Despite these optimizations, the AP50 reaches 92.4%, showing a 1.8% improvement compared to the original model. These results highlight the method's effectiveness in accurately detecting workers' violation behaviors, providing a quantitative basis for its superiority and offering a novel approach for safety management and monitoring at construction sites.

Indexed as

electric power constructionknowledge reasoningmulti-level distillationprogressive distillationviolation detection

Identifiers

PMID39771948
PMCPMC11679740

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked