Evidence map›Paper›PMID 39771747›Full record

ArticleSensors (Basel, Switzerland)2024

Development of Inductive Current Transformer 400/5/1 of Class 0.2S for Frequency Range 50 Hz-5 kHz.

Michal Kaczmarek, Blazej Pacholczyk

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Michal KaczmarekInstitute of Mechatronics and Information Systems, Lodz University of Technology, 90-537 Lodz, Poland.ORCID 0000-0002-6518-9161
Blazej PacholczykInstitute of Mechatronics and Information Systems, Lodz University of Technology, 90-537 Lodz, Poland.ORCID 0009-0002-2980-2341

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper is devoted to the development of a window-type inductive current transformer (iCT) with a rated primary current equal to 400 A and two secondary windings with rated currents of 5 A and 1 A. Its novelty concerns the presentation of this process in the case of an iCT with a 0.2S accuracy class ensured not only for a sinusoidal current of a frequency of 50 Hz but also for the transformation of distorted current in the harmonic frequency range from 50 Hz to 5 kHz. The maximum permissible values of the current error and phase displacement are equal to ±0.2% and ±0.2°, respectively, and are the same as the limiting values for a 50 Hz sinusoidal current of a rated RMS value. In the design process, three materials were considered for the construction of the developed iCT 400/5/1: electrical steel, permalloy and nanocrystalline (Nano). Their wideband properties were analyzed and the choice of the Nano magnetic core was justified with the already-available data in the literature on the basis of elaborated design assumptions. In order to specify its particular type, four magnetic cores with different initial magnetic permeabilities were tested. It was demonstrated that, as far as more favorable magnetic properties also involved increased active power losses in the magnetic core, it was not an appropriate choice for the construction of the iCT, especially for the transformation of the current with a main frequency equal to 50 Hz or 60 Hz.

Indexed as

class 0.2Scurrent errorhigher harmonicsinductive current transformerphase displacementwideband transformation accuracywide frequency

Identifiers

PMID39771747
PMCPMC11679527

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.