Evidence map›Paper›PMID 39771380›Full record

ReviewPolymers2024

Recent Advances in Polyurethane for Artificial Vascular Application.

Hua Ji, Xiaochen Shi, Hongjun Yang

Abstract readReview
In one paragraph

Review in Polymers, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Hua JiWinner Institute for Innovation Research, Winner Medical Co., Ltd., Wuhan 430070, China.
Xiaochen ShiWinner Institute for Innovation Research, Winner Medical Co., Ltd., Wuhan 430070, China.
Hongjun YangCollege of Materials Science and Engineering, Wuhan Textile University, Wuhan 430070, China.

Funding

National Key Research and Development Program of China 2023YFC2412405Wuhan key research and Development Program 2024020702030104
6 · The paper itself

Abstract

Artificial blood vessels made from polyurethane (PU) have been researched for many years but are not yet in clinical use. The main reason was that the PU materials are prone to degradation after contact with blood and will also cause inflammation after long-term implantation. At present, PU has made progress in biostability and biocompatibility, respectively. The PU for artificial blood vessels still requires a balance between material stability and biocompatibility to maintain its long-term stability in vivo, which needs to be further optimized. Based on the requirement of PU materials for artificial vascular applications, this paper views the development of biostable PU, bioactive PU, and bioresorbable PU. The improvement of biostable PU from the monomer structure, chemical composition, and additives are discussed to improve the long-term biostability in vivo. The surface grafting and functionalization methods of bioactive PU to reduce thrombosis and promote endothelialization for improving biocompatibility are summarized. In addition, the bioresorbable PU for tissue-engineered artificial blood vessels is discussed to balance between the degradation rate and mechanical properties. The ideal PU materials for artificial blood vessels must have good mechanical properties, stability, and biocompatibility at the same time. Finally, the application potential of PU materials in artificial vascular is prospected.

Indexed as

artificial blood vesselsbiocompatibilitybiodegradabilitybiostabilitypolyurethane

Identifiers

PMID39771380
PMCPMC11679075

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.