Fabrication of an Integrated, Flexible, Wireless Pressure Sensor Array for the Monitoring of Ventricular Pressure.

Natiely Hernández-Sebastián, Daniela Diaz-Alonso, Bernardino Barrientos-García, Francisco Javier Renero-Carrillo, Wilfrido Calleja-Arriaga

Abstract read
In one paragraph

Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Natiely Hernández-SebastiánCentro de Investigaciones en Óptica, A.C., CIO, Leon 37150, Mexico.ORCID 0000-0003-3800-9003
Daniela Diaz-AlonsoCD-MEMS INAOE, Puebla 72840, Mexico.ORCID 0000-0001-9923-0604
Bernardino Barrientos-GarcíaCentro de Investigaciones en Óptica, A.C., CIO, Leon 37150, Mexico.
Francisco Javier Renero-CarrilloInstituto Nacional de Astrofísica, Óptica y Electrónica-INAOE, Puebla 72840, Mexico.ORCID 0000-0003-1273-4725
Wilfrido Calleja-ArriagaInstituto Nacional de Astrofísica, Óptica y Electrónica-INAOE, Puebla 72840, Mexico.ORCID 0000-0001-5485-1597

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This work presents the design, fabrication, and rigorous validation of a flexible, wireless, capacitive pressure sensor for the full-range continuous monitoring of ventricular pressure. The proposed system consists of an implantable set and an external readout device; both modules were designed to form an RCL resonant circuit for passive, wireless pressure sensing and signal retrieving. Using surface micromachining and flexible electronics techniques, a two-variable capacitor array and a dual-layer planar coil were integrated into a flexible ergonomic substrate, avoiding hybrid-like connections in the implantable set. The proposed arrangement (capacitor array and dual-layer coil) allows us to optimize the operation pressure range and sensing distance. The use of polyimide as both the flexible substrate and the passivation material is a key feature, ensuring a biocompatible, implantable set that is mechanically flexible and can be folded to a compact size to achieve minimally invasive implantation. An external readout device has also been developed using a discrete printed circuit board (PCB) approach to support pressure measurements. The pressure responsivity of the sensor was validated to the laboratory level using a controlled pressure chamber. The results obtained show that the capacitance value of the sensor changed from 5.68 pF to 33.26 pF as the pressure varied from 0 to 300 mmHg. Correspondingly, the resonance frequency of the implantable set shifted from 12.75 MHz to 5.27 MHz. The sensitivity of the capacitive sensor was approximately 0.58 pF/mmHg and the typical response time was 220 ms. The wireless system performance was evaluated in both air and synthetic biological tissue using a Maxwell-Wien bridge circuit. The results showed a sensing distance longer than 3.5 cm, even under moderate misalignment conditions (up to 1.5 cm). The output voltage was successfully measured, ranging from 502.54 mV to 538.29 mV, throughout the full pressure range, with a measurement error of ±2.2 mV.

Indexed as

capacitive pressure sensorflexible electronicsimplantable BioMEMSpassive wireless systemventricular pressure monitoring