ArticleMicromachines2024
Fully Integrated MEMS Micropump and Miniaturized Mass Flow Sensor as Basic Components for a Microdosing System.
Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Despite major advances in the field of actuator technology for microsystems, miniaturized microfluidic actuation systems for mobile devices are still not common in the market. We present a micropump concept and an associated mass flow sensor design, which, in combination, have the potential to form the basis for an integrated microfluidic development platform for microfluidic systems in general and microdosing systems in particular. The micropump combines the use of active valves with an electrostatic drive principle for the pump membrane and the valves, respectively. With a size of only 1.86 mm × 1.86 mm × 0.3 mm, the first prototypes are capable of pumping gaseous media at flow rates of up to 110 μL/min. A specific feature of the presented micropump is that the pumping direction is perpendicular to the chip surface. The corresponding flow sensor combines the principle of hot-wire anemometry with a very small footprint of only 1.4 mm × 1.4 mm × 0.4 mm. The main innovation is that the hot wires are fixed inside a through-hole in the substrate of the microchip, so that the flow direction of the fluid to be measured is perpendicular to the chip surface, which enables direct integration with the presented micropump. Detection thresholds of around 10 μL/min and measuring ranges of up to 20 mL/min can be achieved with the first prototypes, without dedicated evaluation electronics.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.