Evidence map›Paper›PMID 39769772›Full record

ArticleMaterials (Basel, Switzerland)2024

A New Methodology for Selecting CT Scanning Parameters Depending on the Density of Materials.

Ksenia Ostrowska, Jerzy Sładek, Paweł Wołkanowski, Ireneusz Dominik, Danuta Owczarek, Marek Nykiel, Krzysztof Tomczyk, Michał Stoliński

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ksenia OstrowskaMechanical Faculty, Cracow University of Technology, Jana Pawła II 37 avenue, 31-864 Krakow, Poland.
Jerzy SładekMechanical Faculty, Cracow University of Technology, Jana Pawła II 37 avenue, 31-864 Krakow, Poland.ORCID 0000-0002-5991-4988
Paweł WołkanowskiMechanical Faculty, Cracow University of Technology, Jana Pawła II 37 avenue, 31-864 Krakow, Poland.
Ireneusz DominikFaculty of Mechanical Engineering and Robotics, AGH University of Krakow, al. Adama Mickiewicza 30, 30-059 Krakow, Poland.ORCID 0000-0002-2304-7763
Danuta OwczarekMechanical Faculty, Cracow University of Technology, Jana Pawła II 37 avenue, 31-864 Krakow, Poland.ORCID 0009-0002-1824-9130
Marek NykielFaculty of Materials Engineering and Physics, Cracow University of Technology, Jana Pawła II 37 avenue, 31-864 Krakow, Poland.ORCID 0000-0002-2925-5889
Krzysztof TomczykFaculty of Electrical and Computer Engineering, Cracow University of Technology, Warszawska 24, 31-155 Krakow, Poland.ORCID 0000-0002-8922-6529
Michał StolińskiMechanical Faculty, Cracow University of Technology, Jana Pawła II 37 avenue, 31-864 Krakow, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The CT (computed tomography) scanner has been used for many years now not only for medical measurements but also in many industries, for example, in defectoscopy for measuring sheet thickness and checking the joining of materials, as well as for measuring the geometry of individual components. This type of scanner is a good complement to coordinate contact and non-contact measurements for intra-structural measurements and inaccessible places. The variety of materials, however, makes it very difficult to select individual CT parameters. In this paper, a curve for selecting the maximum and minimum voltage of the lamp depending on the density of a given material is determined and an interpolation polynomial (1d with a third-degree polynomial) is used, by defining third-degree glued functions (cubic spline) to determine intermediate voltage values to a given material density, so as to determine full data ranges. This approach can facilitate the work of selecting scanning parameters for non-destructive testing, as this is a difficult process and sometimes consumes half of the measurement time. The practical experiments were carried out at the Accredited Coordinate Metrology Laboratory to develop a multi-criteria matrix for selecting CT measurement parameters for measurement accuracy. This approach reduced the time by an average of half an hour and effectively optimized the selection of scanning parameters.

Indexed as

coordinate measurementlinear radiation absorption coefficientmaterial densitymeasurement accuracyX-ray computed tomography

Identifiers

PMID39769772
PMCPMC11678745

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.