Evidence map›Paper›PMID 39768391›Full record

ArticleLife (Basel, Switzerland)2024

Comparative Biomechanical Analysis of Kirschner Wire Fixation in Dorsally Displaced Distal Radius Fractures.

Awad Dmour, Ștefan-Lucian Toma, Alin-Marian Cazac, Stefan Dragos Tirnovanu, Nicoleta Dima, Bianca-Ana Dmour, Dragos Cristian Popescu, Ovidiu Alexa

Abstract read
In one paragraph

Article in Life (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Awad DmourDepartment of Orthopedics and Traumatology, Faculty of Medicine, "Grigore T. Popa" University of Medicine and Pharmacy, 700115 Iasi, Romania.ORCID 0009-0005-1154-7145
Ștefan-Lucian TomaMaterials Science Department, Materials Science and Engineering Faculty, Gheorghe Asachi Technical University of Iasi, 700050 Iasi, Romania.ORCID 0000-0003-4623-9175
Alin-Marian CazacMaterials Science Department, Materials Science and Engineering Faculty, Gheorghe Asachi Technical University of Iasi, 700050 Iasi, Romania.ORCID 0000-0001-8268-5530
Stefan Dragos TirnovanuDepartment of Orthopedics and Traumatology, Faculty of Medicine, "Grigore T. Popa" University of Medicine and Pharmacy, 700115 Iasi, Romania.ORCID 0009-0006-2624-8890
Nicoleta DimaDepartment of Internal Medicine, "Grigore T. Popa" University of Medicine and Pharmacy, 700115 Iași, Romania.ORCID 0000-0002-8276-835X
Bianca-Ana DmourDepartment of Internal Medicine, "Grigore T. Popa" University of Medicine and Pharmacy, 700115 Iași, Romania.
Dragos Cristian PopescuDepartment of Orthopedics and Traumatology, Faculty of Medicine, "Grigore T. Popa" University of Medicine and Pharmacy, 700115 Iasi, Romania.
Ovidiu AlexaDepartment of Orthopedics and Traumatology, Faculty of Medicine, "Grigore T. Popa" University of Medicine and Pharmacy, 700115 Iasi, Romania.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study aims to evaluate and compare the biomechanical performance of two Kirschner (K) wire configurations-the intra-focal and interfragmentary techniques-for the fixation of dorsally displaced distal radius fractures. The study also assesses the impact of K-wire diameter (1.6 mm vs. 2.0 mm) on mechanical stability.

methodsSixty fresh turkey tarsometatarsus bones were selected and divided into four groups based on the K-wire configuration and diameter used. Fractures were created at standardized locations, and each bone was stabilized using either the intra-focal also known as modified Kapandji (Ka) or interfragmentary technique. Mechanical testing, including axial compression and flexion tests, was performed to assess the biomechanical stability of each configuration.

resultsThe interfragmentary configuration consistently demonstrated superior biomechanical performance compared to the intra-focal technique. Specifically, the use of 2.0 mm K-wires resulted in significantly higher axial stiffness (13.28 MPa) and load at break (3070 N) compared to the 1.5 mm wires. Confidence intervals further supported the robustness of these findings. The interfragmentary technique, especially with thicker K-wires, provided greater load-bearing capacity and stiffness.

conclusionThe interfragmentary technique with 2.0 mm K-wires offers superior mechanical stability compared to the intra-focal technique, making it the preferred choice for stabilizing comminuted extra-articular distal radius fractures. These findings suggest that adopting this technique may reduce the risk of postoperative complications such as fracture displacement or malunion. Further research involving osteoporotic bone models and clinical trials is recommended to validate these findings in real-world settings.

Indexed as

biomechanical comparisondistal radius fracturesinterfragmentary techniqueintra-focal techniqueKapandjiturkey tarsometatarsus model

Identifiers

PMID39768391
PMCPMC11677149

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.