The Development of a System for Elbow Joint Range of Motion Measurement Based on Image Recognition and Myoelectric Signals.

Hsuan-Kai Kao, Yi-Chao Wu, Chi-Heng Lu, Xiu-Ling Hou, Tsair-Fwu Lee, Chiu-Ching Tuan

Abstract read
In one paragraph

Article in Life (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hsuan-Kai KaoDepartment of Orthopedic Surgery, Chang Gung Memorial Hospital at Linkou, Taoyuan 33305, Taiwan.ORCID 0000-0002-1125-0932
Yi-Chao WuDepartment of Electronic Engineering, National Yunlin University of Science and Technology, Yunlin 64030, Taiwan.ORCID 0009-0005-6665-583X
Chi-Heng LuDepartment of Radiation Oncology, Chang Gung Memorial Hospital at Linkou, Taoyuan 33305, Taiwan.ORCID 0000-0001-9348-0899
Xiu-Ling HouDepartment of Electronic Engineering, National Taipei University of Technology, Taipei 10608, Taiwan.
Tsair-Fwu LeeMedical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Kaohsiung 80778, Taiwan.ORCID 0000-0002-3112-3594
Chiu-Ching TuanDepartment of Electronic Engineering, National Taipei University of Technology, Taipei 10608, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

After a fracture, patients have reduced willingness to bend and extend their elbow joint due to pain, resulting in muscle atrophy, contracture, and stiffness around the elbow. Moreover, this may lead to progressive atrophy of the muscles around the elbow, resulting in permanent functional loss. Currently, a goniometer is used to measure the range of motion, ROM, to evaluate the recovery of the affected limb. However, the measurement process can cause measurement errors ranging from 4 to 5 degrees due to unskilled operation or inaccurate placement, leading to inaccurate judgments of the recovery of the affected limb. In addition, the current measurement methods do not include an assessment of muscle endurance. In this paper, the proposed device combines image recognition and a myoelectric signal sensor to measure the joint movement angle and muscle endurance. The movement angle of the elbow joint is measured using image recognition. Muscle endurance is measured using the myoelectric signal sensor. The measured data are transmitted to a cloud database via an app we have proposed to help medical staff track a patient's recovery status. The average error value of static image recognition and verification is up to 0.84 degrees. The average error value of dynamic image recognition and verification is less than 1%. The average error of total harmonic distortion (THD) verified by the myoelectric signal sensor is less than ±3%. It was proven that our system could be applied to measuring elbow joint range of motion. Since this is pilot research, most of the measurement subjects are healthy people without dysfunction in arm movement, and it is difficult to observe differences in the measurement results. In the future, experiments will be conducted on patients with elbow fractures through the IRB. This is expected to achieve the effect of encouraging patients to be actively rehabilitated at home through their measurement data and images of their actions being displayed in real time using our cheap and compact device and app.

Indexed as

elbow joint range of motion measurementimage recognitionmyoelectric signalrehabilitationtotal harmonic distortion

Identifiers

PMID39768243
PMCPMC11679987

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.