Evidence map›Paper›PMID 39768060›Full record

ReviewBioengineering (Basel, Switzerland)2024

The Biomechanics of Spinal Orthoses for Adolescent Idiopathic Scoliosis: A Systematic Review of the Controlling Forces.

Changliang Luo, Huidong Wu, Wei Liu, Yuyan Luo, Yi Jie, Christina Zong-Hao Ma, Mansang Wong

Abstract readReview
In one paragraph

Review in Bioengineering (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Changliang LuoDepartment of Prosthetic and Orthotic Engineering, School of Rehabilitation, Kunming Medical University, Kunming 650032, China.ORCID 0000-0002-6506-5740
Huidong WuDepartment of Prosthetic and Orthotic Engineering, School of Rehabilitation, Kunming Medical University, Kunming 650032, China.
Wei LiuDepartment of Prosthetic and Orthotic Engineering, School of Rehabilitation, Kunming Medical University, Kunming 650032, China.
Yuyan LuoDepartment of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR 999077, China.ORCID 0009-0002-5544-7101
Yi JieDepartment of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR 999077, China.
Christina Zong-Hao MaDepartment of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR 999077, China.ORCID 0000-0001-6507-2329
Mansang WongDepartment of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR 999077, China.

Funding

Basic Research Project of Yunnan Provincial Science and Technology Department-Funds for Young 202201AU070165National Natural Science Foundation of China-Regional Fund 82360365Yunnan Provincial Science and Technology Department-Kunming Medical University Joint Special Fund for Applied Basic Research 202301AY070001-260
6 · The paper itself

Abstract

backgroundOrthotic treatment is a well-acknowledged conservative treatment for moderate adolescent idiopathic scoliosis (AIS). The efficacy of this treatment is significantly determined by the forces applied to the bodies of patients. However, there is uncertainty regarding the optimal force levels that should be applied to the patient's torso by spinal orthosis. This study aims to identify reference values for the controlling forces in AIS management.

methodsA comprehensive literature search was performed in five databases (PubMed, Scopus, Cochrane Library, CINAHL, and Web of Science). Only studies written in English and covering the force/pressure measurements of spinal orthosis for the treatment of AIS were included, without publication date restrictions. The methodological index for non-randomized studies (MINORS) was employed for the methodological quality assessment, and force measurements were standardized to pressure in kilopascals (kPa) for comparison.

resultsFrom the initial 10,452 records, 10 studies were admitted for the final analysis. All the included studies reported the interface pressure between the thoracic (T) pad and patient's trunk, and seven studies evaluated the pressure from the thoracolumbar/lumbar (TL/L) pad. These studies used different pressure sensors or transducers with the range from 5.6 to 82.5 kPa for the T pads, and 4.8 to 85.1 kPa for the TL/L pads. Four studies reported strap tensions of 26.8 to 60.4 N. Higher strap tension was correlated with increased interface pressure (r = 0.84).

conclusionThe mean strap tension was 42.5 N, the median interface pressure of the T pads was 8.75 kPa, and the median pressure of TL/L regions was 7.11 kPa without the outliers. The findings provide a baseline value for designing adjustable straps and strategically distributing pressure in orthoses.

Indexed as

AISbiomechanicscorrective forcespinal orthosis

Identifiers

PMID39768060
PMCPMC11673803

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.