Laser-Based Length-Measuring Board for the Measurement of Infant Body Length from Outside an Incubator: Proposal and Assessment of a Model.

Luís Pereira-da-Silva, Rafael B Henriques, Daniel Virella, Andreia Mascarenhas, Ana Luísa Papoila, Marta Alves, Horácio Fernandes

Abstract read
In one paragraph

Article in Children (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Luís Pereira-da-SilvaNeonatology Unit, Hospital Dona Estefânia and Maternidade Dr. Alfredo da Costa, Unidade de Saúde Local São José, Centro Clínico Académico de Lisboa, 1169-045 Lisbon, Portugal.ORCID 0000-0002-6480-1048
Rafael B HenriquesInstituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisbon, Portugal.ORCID 0000-0003-0585-0904
Daniel VirellaNeonatology Unit, Hospital Dona Estefânia and Maternidade Dr. Alfredo da Costa, Unidade de Saúde Local São José, Centro Clínico Académico de Lisboa, 1169-045 Lisbon, Portugal.
Andreia MascarenhasNeonatology Unit, Hospital Dona Estefânia and Maternidade Dr. Alfredo da Costa, Unidade de Saúde Local São José, Centro Clínico Académico de Lisboa, 1169-045 Lisbon, Portugal.
Ana Luísa PapoilaResearch Unit, Unidade de Saúde Local São José, Centro Clínico Académico de Lisboa, 1169-045 Lisbon, Portugal.
Marta AlvesResearch Unit, Unidade de Saúde Local São José, Centro Clínico Académico de Lisboa, 1169-045 Lisbon, Portugal.ORCID 0000-0002-7421-8550
Horácio FernandesInstituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisbon, Portugal.ORCID 0000-0001-6542-7767

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionOpening the incubator side wall to insert a non-sterile length-measuring device carries the risk of microbial contamination and thermal instability for preterm infants. To reduce this inconvenience, a laser-based length-measuring board is proposed to measure body length from outside the incubator.

methodsThis device has two laser-line-shaped cursors which can be pointed to opposite ends of a segment to be measured. It is attached to the outer side of one of the incubator's side walls in such a manner as to ensure that its axis is parallel to the longitudinal axis of the segment. To validate the measurements made with this model, a calibrated caliper consisting of a conventional rigid length-measuring board with a resolution of 0.05 mm was constructed to serve as a reference. Crown-heel length was measured in a sample of 45 infants, including 32 preterm and 13 term infants of corrected gestational age at the time of measurement.

resultsGood intra-observer variability was obtained. Near-perfect statistical agreement was found between measurements with both devices, with concordance correlation coefficients of 0.994 (95% CI: 0.990; 0.996) in preterm infants and 0.994 (95% CI: 0.988, 0.998) in infants at term. The clinical relevance of the agreement between measurements was assessed by a Bland-Altman plot, and the difference may reach clinical relevance (up to 1 cm) but without evidence of proportional bias.

conclusionThe proposed validated laser-based length-measuring board offers a suitable alternative to conventional length-measuring boards for contactless measurement of infant body length.

Indexed as

calipercontactless measurementincubatorlaserlength-measuring boardpreterm infant

Identifiers

PMID39767973
PMCPMC11727513

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.