Evidence map›Paper›PMID 39767254›Full record

ArticleDiagnostics (Basel, Switzerland)2024

The Comparison of Accuracy of Post Space Digital Impressions Made by Three Different Intraoral Scanners: An In Vitro Study.

Abdullah A Meshni, Saurabh Jain, Hanan Nasser Marie Osaysi, Khadijah Nasser Hezam, Samar Samir Gomaan Adlan

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Abdullah A MeshniDepartment of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia.
Saurabh JainDepartment of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia.ORCID 0000-0002-0071-4068
Hanan Nasser Marie OsaysiIntern Clinic, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia.
Khadijah Nasser HezamIntern Clinic, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia.
Samar Samir Gomaan AdlanMINA Dental Clinic, Ash Shati, Jazan 82725, Saudi Arabia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

objectivesThe present study aims to assess and compare the accuracy of post-space impressions captured by three different intraoral scanners (IOS) using various canal diameters.

methodsThree extracted natural maxillary central incisors were selected and prepared for a 1 mm wide margin and a 3 mm ferrule. All steps required for the endodontic procedure were performed, and the post space was prepared using post drills. The post length was kept constant at 12 mm, whereas the width was varied (Group 1: 1.4 mm, Group 2: 1.6 mm, and Group 3: 1.8 mm). Three IOSs (Trios3, iTero2, and Medit i700) were used to acquire a digital impression of the prepared post space. Each tooth was scanned 10 times by each scanner. So, in the end, 90 digital images were recorded, and the STL files were stored. GC Pattern resin was used to fabricate resin post and core patterns, which were scanned using an extraoral scanner (EOS). The STL file obtained was used as the reference file. To evaluate the trueness of the tested IOSs, each three-dimensional scan from an IOS was superimposed on the reference scan with the help of the Medit Design software 2.1.4. The software generates color plots and gives numerical values as deviations in the Root mean square (RMS) for the variance between the two superimposed scans. The data collected was tabulated for statistical analysis. One Way ANOVA was used to test the significance difference between three different IOSs, followed by Bonferroni Post-hoc test pairwise test to identify the differences between every two different IOS. Statistical significance was set at

resultsThe mean deviation for trueness in post space impression values recorded by the Medit i700 was highest among groups 1, 2, and 3 [0.825 (±0.071), 0.673 (±0.042) and 0.516 (±0.039), respectively], followed by iTero2 [0.738 (±0.081), 0.569 (±0.043) and 0.470 (±0.037), respectively] and Trios3 [0.714 (±0.062), 0.530 (±0.040) and 0.418 (±0.024), respectively]. Significant differences were found between the groups for all three IOSs (Trios3:

conclusionsWithin the limitations of this study, it can be concluded that Trios3 IOS has higher accuracy (as it exhibited minimal deviation for trueness) in recording post space, followed by iTero2 and Mediti700 IOS. As the diameter of the post space is increased, the accuracy of recording by IOS increases. For all the tested IOSs (except for Trios3 and iTero2, when used to record post space with 1.8 mm canal diameter), the deviations in trueness were higher than the clinically acceptable limits. Thus, IOSs should be used cautiously when recording impressions of post spaces.

Indexed as

accuracydigital impressionintraoral scannerpost and corepost spacepost space impressiontrueness

Identifiers

PMID39767254
PMCPMC11675620

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.