ArticleActa otorhinolaryngologica Italica : organo ufficiale della Societa italiana di otorinolaringologia e chirurgia cervico-facciale2024
Effects of face protector devices on acoustic parameters of voice.
Article in Acta otorhinolaryngologica Italica : organo ufficiale della Societa italiana di otorinolaringologia e chirurgia cervico-facciale, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objectives: The SARS-CoV-2 pandemic required the use of personal protective equipment (PPE) in medical and social contexts to reduce exposure and prevent pathogen transmission. This study aims to analyse possible changes in voice and speech parameters with and without PPE. Methods: Speech samples using different types of PPE were obtained. Recordings were then analysed using PRAAT software (version 6.1.42). Statistical analysis was conducted using ANOVA in Jamovi software. A post-hoc test was performed to compare PPE-related results. Results: Statistically significant differences were found in Cepstral Peak of Prominence-Smoothed, Harmonic to Noise Ratio (HNR), slope of Long-Term Average Spectrum (LTAS), tilt of trendline through LTAS, shimmer parameters, HNR mean and standard deviation of vowels, vowels and consonants formants. HNR values increased whereas shimmer parameters and formant values reduced using PPE [PPE combined>filtering face piece (FFP)> surgical masks>no PPE]. Conclusions: Our data show improvement in many parameters of voice and speech quality and modification of speech articulation when using masks, particularly in case of combined PPE. The most relevant changes were found with a combination of face shield and FFP2 masks. This may be due to unconscious improvements in speech articulation and increased demand on vocal folds to achieve better speech intelligibility.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials