Evidence map›Paper›PMID 39763291›Full record

ArticleLab on a chip2025

Injury-on-a-chip for modelling microvascular trauma-induced coagulation.

Halston Deal, Elizabeth M Byrnes, Sanika Pandit, Anastasia Sheridan, Ashley C Brown, Michael Daniele

Abstract read
In one paragraph

Article in Lab on a chip, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Halston DealJoint Department of Biomedical Engineering, North Carolina State University and University of North Carolina, Chapel Hill, 1840 Entrepreneur Dr., Raleigh, NC, 27695 USA. mdaniel6@ncsu.edu.
Elizabeth M ByrnesJoint Department of Biomedical Engineering, North Carolina State University and University of North Carolina, Chapel Hill, 1840 Entrepreneur Dr., Raleigh, NC, 27695 USA. mdaniel6@ncsu.edu.
Sanika PanditJoint Department of Biomedical Engineering, North Carolina State University and University of North Carolina, Chapel Hill, 1840 Entrepreneur Dr., Raleigh, NC, 27695 USA. mdaniel6@ncsu.edu.
Anastasia SheridanJoint Department of Biomedical Engineering, North Carolina State University and University of North Carolina, Chapel Hill, 1840 Entrepreneur Dr., Raleigh, NC, 27695 USA. mdaniel6@ncsu.edu.
Ashley C BrownJoint Department of Biomedical Engineering, North Carolina State University and University of North Carolina, Chapel Hill, 1840 Entrepreneur Dr., Raleigh, NC, 27695 USA. mdaniel6@ncsu.edu.ORCID 0000-0001-6995-1785
Michael DanieleJoint Department of Biomedical Engineering, North Carolina State University and University of North Carolina, Chapel Hill, 1840 Entrepreneur Dr., Raleigh, NC, 27695 USA. mdaniel6@ncsu.edu.ORCID 0000-0002-2016-4091

Funding

NC STATE MOLECULAR BIOTECHNOLOGY TRAINING PROGRAM (MBTP)T32GM133366 · NIGMS · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI Jason M. Haugh, Robert M Kelly · 2020 to 2026
$3.3M
Training Grant in Comparative Molecular MedicineT32GM133393 · NIGMS · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI Matthew B Fisher, Caroline Laplante · 2021 to 2026
$1.7M
NIGMS NIH HHS T32 GM133366NIGMS NIH HHS T32 GM133393
6 · The paper itself

Abstract

Blood coagulation is a highly regulated injury response that features polymerization of fibrin fibers to prevent the passage of blood from a damaged vascular endothelium. A growing body of research seeks to monitor coagulation in microfluidic systems but fails to capture coagulation as a response to disruption of the vascular endothelium. Here we present a device that allows compression injury of a defined segment of a microfluidic vascular endothelium and the assessment of coagulation at the injury site. This pressure injury-on-a-chip (PINCH) device allows visualization of coagulation as the accumulation of fluorescent fibrin at injury sites. Quantification of fluorescent fibrin levels upstream of and at injury sites confirm that pre-treating vascular endothelium with fluid shear stress helps capture coagulation as an injury response. We leverage the PINCH devices to demonstrate the limited coagulation response of type A hemophiliacs and evaluate the performance of hemostatic microparticles and fibrinolytic nanoparticles. Our findings and the straightforward fabrication of the PINCH devices make it a promising choice for additional screening of hemostatic therapeutics.

Indexed as

Blood CoagulationLab-On-A-Chip DevicesMicrofluidic Analytical TechniquesMicrovesselsEndothelium, VascularEquipment DesignFibrinHumansFibrin

Identifiers

PMID39763291
PMCPMC11704661

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.