Evidence map›Paper›PMID 39762868›Full record

ArticleBMC musculoskeletal disorders2025

Elbow rotation affects the accuracy of rotational formulas: validation of a modified method.

Yong Liu, Xiaoju Liang, Jianping Sun, Jining Qu, Bohai Qi, Yating Yang, Qiang Jie

Abstract readValidation Study
In one paragraph

Article in BMC musculoskeletal disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yong Liu *Pediatric Orthopedic Hospital, Honghui Hospital, Xi'an Jiao tong University, Xi'an, 710000, China.
Xiaoju Liang *Pediatric Orthopedic Hospital, Honghui Hospital, Xi'an Jiao tong University, Xi'an, 710000, China.
Jianping SunPediatric Orthopedic Hospital, Honghui Hospital, Xi'an Jiao tong University, Xi'an, 710000, China.
Jining QuPediatric Orthopedic Hospital, Honghui Hospital, Xi'an Jiao tong University, Xi'an, 710000, China.
Bohai QiPediatric Orthopedic Hospital, Honghui Hospital, Xi'an Jiao tong University, Xi'an, 710000, China.
Yating YangPediatric Orthopedic Hospital, Honghui Hospital, Xi'an Jiao tong University, Xi'an, 710000, China.
Qiang JiePediatric Orthopedic Hospital, Honghui Hospital, Xi'an Jiao tong University, Xi'an, 710000, China. jieqiangchina@126.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSupracondylar humerus fractures (SCHFs) are the most common elbow fractures in children and are typically treated with closed reduction and Kirschner pin fixation. However, varying degrees of residual rotational displacement may remain after closed reduction. Several methods exist to assess rotational displacement, but none account for the effect of elbow rotation on the results. We hypothesize that the accuracy of the primitive rotational calculation formula (PRCF) decreases as elbow rotation increases and propose a modified rotational calculation formula (MRCF). This study aims to investigate the impact of elbow rotation on PRCF and validate the reliability of MRCF.

methodsMimics software was used to reconstruct the distal humerus in a child and create a transverse SCHF, which was then subjected to X-ray fluoroscopy simulation. Axial rotational displacement was simulated in 5° increments, from 0° to 45°. Internal and external elbow rotations were simulated by adjusting the "LAO" and "RAO" angles. Five physicians measured and calculated displacement using both the primitive and modified rotational calculation formulas.

resultsThe PRCF method showed an average error of 17.98° ± 12.31° with a maximum error of 46.46%. Additionally, 13% of measurements had an error under 3°, and 29% had an error under 10°. With MRCF, the mean error for internal rotation was 2.04° ± 1.67°, with a maximum of 6.09%; 68% of cases had an error under 3° and 94% under 5%. For external rotation, the mean error was 2.74° ± 2.66°, with a maximum of 8.29%; 57% of cases had an error under 3° and 98% under 8°. Intraclass correlation coefficients for the five physicians were 0.966 for internal rotation and 0.989 for external rotation.

conclusionsThis study demonstrates that the accuracy of PRCF decreases as elbow rotation increases, supporting our hypothesis. MRCF effectively addresses the limitations of PRCF and provides stable, accurate measurements of rotational displacement even with varying elbow rotations. Accurate assessment of rotational displacement in the horizontal plane is essential to understanding the relationship between residual rotational displacement and SCHF prognosis. MRCF will play a critical role in this process.

Indexed as

Elbow JointHumeral FracturesChildElbow InjuriesFluoroscopyHumansRange of Motion, ArticularReproducibility of ResultsRotation3D fluoroscopy simulationKirschner wire fixationRotational calculationRotational displacementSupracondylar humerus fractures

Identifiers

PMID39762868
PMCPMC11702081

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.