Evidence map›Paper›PMID 39762685›Full record

ArticleJournal of robotic surgery2025

The use of laser-assisted cart positioning significantly reduces the docking time of multimodular robotic systems.

Martin Baunacke, Christopher Hirtsiefer, Roman Herout, Sherif Mehralivand, Susanne Oelkers, Oliver Kaske, Claudia Franz, Christian Thomas

Abstract read
In one paragraph

Article in Journal of robotic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Martin BaunackeDepartment of Urology, Medical Faculty Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Germany. martin.baunacke@ukdd.de.ORCID http://orcid.org/0000-0002-5601-7587
Christopher HirtsieferDepartment of Urology, Medical Faculty Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Germany.
Roman HeroutDepartment of Urology, Medical Faculty Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Germany.
Sherif MehralivandDepartment of Urology, Medical Faculty Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Germany.
Susanne OelkersDepartment of Urology, Medical Faculty Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Germany.
Oliver KaskeDepartment of Medical Technology, Medical Faculty Carl Gustav Carus, TU Dresden, Dresden, Germany.
Claudia FranzDepartment of Urology, Medical Faculty Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Germany.
Christian ThomasDepartment of Urology, Medical Faculty Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The Hugo RAS system is characterized by its multimodular design, which leads to an increased docking effort. Exact data for docking time and the learning curve is missing. We describe for the first time the use of a laser-guided cart positioning to reduce the docking time. In this prospective monocentric study, the docking time was evalutated for a consecutive series of pelvic surgeries with the Hugo RAS system. In a subgroup, a cross-line laser was adapted at the cart for positioning using fix points at the ceiling. The medical personnel were classified as "inexperienced" with ≤ 5 consecutive dockings and as "experienced" with > 5 consecutive dockings. From 10/2023 to 08/2024, 82 procedures were performed with the Hugo RAS. For the evaluation 75 procedures could be considered. The mean docking time was 7.6 ± 3.5 min. There was a reduction in docking time from 13.5 ± 3.7 min in the first 5 procedures to 4.4 ± 0.9 min in the last 5 procedures (p < 0.001). Docking with laser (n = 45) was faster than without laser (n = 30) (6.2 ± 2.5 vs. 9.8 ± 3.7 min, p < 0.001). Faster docking time was observed with inexperienced surgical nursing staff with laser than without laser (10.4 ± 3.7 vs. 5.4 ± 1.4 min; p < 0.001). With experienced nursing staff, the laser had no influence (6.6 ± 1.3 vs. 6.7 ± 2.9 min; p = 0.9). As a reference docking time for daVinci Xi procedures was 2.4 ± 1.7 min (n = 5). Laser-guided cart positioning has a significant impact on docking time, especially for unexperienced medical personnel. Especially in the times of experienced staff shortage, laser-guided cart positioning can save operating time.

Indexed as

Operative TimeRobotic Surgical ProceduresFemaleHumansLasersLearning CurveMaleMiddle AgedPelvisProspective StudiesTime FactorsDockingHugo RASMultimodular robotic systemsRadical prostatectomy

Identifiers

PMID39762685
PMCPMC11703870

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked