Evidence map›Paper›PMID 39762554›Full record

ArticleCommunications medicine2025

Artificial intelligence for hemodynamic monitoring with a wearable electrocardiogram monitor.

Daphne E Schlesinger, Ridwan Alam, Roey Ringel, Eugene Pomerantsev, Srikanth Devireddy, Pinak Shah, Joseph Garasic, Collin M Stultz

Abstract read
In one paragraph

Article in Communications medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Daphne E Schlesinger *Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA, USA.
Ridwan Alam *Research Laboratory of Electronics, MIT, Cambridge, MA, USA.ORCID http://orcid.org/0000-0002-4332-4051
Roey RingelDivision of Cardiology, Massachusetts General Hospital, Boston, MA, USA.ORCID http://orcid.org/0000-0003-2362-8258
Eugene PomerantsevDivision of Cardiology, Massachusetts General Hospital, Boston, MA, USA.
Srikanth DevireddyHarvard Medical School, Boston, MA, USA.
Pinak ShahHarvard Medical School, Boston, MA, USA.
Joseph GarasicHarvard Medical School, Boston, MA, USA.
Collin M StultzHarvard-MIT Division of Health Sciences and Technology, Cambridge, MA, USA. cmstultz@mit.edu.ORCID http://orcid.org/0000-0002-3415-242X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe ability to non-invasively measure left atrial pressure would facilitate the identification of patients at risk of pulmonary congestion and guide proactive heart failure care. Wearable cardiac monitors, which record single-lead electrocardiogram data, provide information that can be leveraged to infer left atrial pressures.

methodsWe developed a deep neural network using single-lead electrocardiogram data to determine when the left atrial pressure is elevated. The model was developed and internally evaluated using a cohort of 6739 samples from the Massachusetts General Hospital (MGH) and externally validated on a cohort of 4620 samples from a second institution. We then evaluated model on patch-monitor electrocardiographic data on a small prospective cohort.

resultsThe model achieves an area under the receiver operating characteristic curve of 0.80 for detecting elevated left atrial pressures on an internal holdout dataset from MGH and 0.76 on an external validation set from a second institution. A further prospective dataset was obtained using single-lead electrocardiogram data with a patch-monitor from patients who underwent right heart catheterization at MGH. Evaluation of the model on this dataset yielded an area under the receiver operating characteristic curve of 0.875 for identifying elevated left atrial pressures for electrocardiogram signals acquired close to the time of the right heart catheterization procedure.

conclusionsThese results demonstrate the utility and the potential of ambulatory cardiac hemodynamic monitoring with electrocardiogram patch-monitors.

Identifiers

PMID39762554
PMCPMC11704156

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.