ArticleOrthopaedic surgery2025
Biomechanical Analysis and Solution Suggestions of Screw Replacement Scenarios in Femoral Neck Fracture Surgeries: Finite Element Method.
Article in Orthopaedic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Biomechanical evaluation of a lower-limb implant model under gait and stumbling conditions using finite element analysis.Scientific reports · 2025Article
- Long-Term Outcomes of Triple Cannulated Compression Screws Combined With Bone Graft Sleeve Parallel Implantation of DBM Crunch Internal Fixation for the Treatment of Femoral Neck Fractures in Middle-Aged and Young Adults.Orthopaedic surgery · 2025Article
- Comparative study by FEM of different liners of a transfemoral amputated lower limb.Scientific reports · 2025Article
- The influence of proximal femur CT value on stress distribution and stability in intertrochanteric fracture after PFNA fixation: a finite element analysis.BMC musculoskeletal disorders · 2025Article
- Biomechanical evaluation of femoral neck system versus non-sliding fixation in the treatment of young patients with Pauwels type III femoral neck fractures: a finite element analysis.BMC musculoskeletal disorders · 2025Article
- Title of the study: finite element analysis of five internal fixation modalities for Schatzker type IV‒C tibial plateau fractures.BMC musculoskeletal disorders · 2025Article
- Biomechanical properties of off-axis screw in the treatment of vertical femoral neck fractures: a finite element analysis.BMC musculoskeletal disorders · 2025Article
- A novel external fixation for treating tibial fractures: a finite element and biomechanical study.Journal of orthopaedic surgery and research · 2025Article
- Case Report: A severe case of traumatic ankle fracture-dislocation with medial malleolar bony defect and 5-year follow-up.Frontiers in surgery · 2025Article
- A novel injury mechanism of trans-styloid palmar-divergent dislocation of the lunate and scaphoid: a case report.Frontiers in surgery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveDespite several surgical options, there has yet to be a consensus on the best treatment for femoral neck fracture (FNF) due to higher complication rates compared to other bone fractures. This study aims to examine the possible consequences and solution suggestions of changing screws during surgery for various reasons in FNF surgical treatment from a biomechanical perspective.
methodFNF and treatment materials were analyzed biomechanically using a package program based on the finite element method (FEM). This study created a solid model with images of femur bone tomography. Dynamic hip screws (DHS), cannulated screws (CCS), and medial buttress plates (MBP) were obtained by making three-dimensional designs. The required elements for the models were assigned, and the material properties of the elements were defined. The solutions were obtained as crack distance and deformation results after defining the boundary conditions and applying the necessary loading.
resultsThe strain and crack distance values created by six models on the fracture line under different parameters were obtained, and the numerical results were evaluated. The DHS and CCS models produced the highest crack distance and deformation values when all screws were loose. The lowest values were obtained in the intact-85 model when all CCS were tight. When the results are evaluated, it is seen that the MBP has a decreasing effect on the results. Mechanical evaluation of six different options used in femoral neck fractures was performed. 85 mm CCS applied to our standard model gave the best results, while the use of 80 mm CCS in the same model showed promising results compared to other models. It is understood that CCS have the best stability even in loosening models with the medial support plate. Different models are from intact-85 mm DHS+1CS+MBP to DHS+1CS, which was worked with LSR+USR-2, according to decreasing stability.
conclusionThis study offers various biomechanical solutions to possible intraoperative problems in FNF treatment. The following results were obtained from the study data. When the CCS needs to be lengthened or replaced, it is appropriate to use the CCS with the MBP. A single anti-rotation screw is sufficient for lag screw extensions of the DHS plate, and the MBP may be a savior procedure in surgery.