Evidence map›Paper›PMID 39760966›Full record

ArticleMedical & biological engineering & computing2025

Machine learning models based on FEM simulation of hoop mode vibrations to enable ultrasonic cuffless measurement of blood pressure.

Ravinder Kumar, Vishal Kumar, Collin Rich, David Lemmerhirt, Balendra, J Brian Fowlkes, Ashish Kumar Sahani

Erratum issuedAbstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

Ravinder KumarDepartment of Bioengineering, University of Pittsburgh, Swanson School of Engineering, 302 Benedum Hall 3700 O'Hara Street, Pittsburgh, PA, 15260, USA. ravinderkumar702@gmail.com.ORCID http://orcid.org/0000-0002-4454-8698
Vishal KumarDepartment of Biomedical Engineering, Indian Institute of Technology, Ropar, Punjab, India.
Collin RichSonetics Ultrasound Inc, Ann Arbor, MI, USA.
David LemmerhirtSonetics Ultrasound Inc, Ann Arbor, MI, USA.
BalendraDepartment of Biomedical Engineering, Indian Institute of Technology, Ropar, Punjab, India.
J Brian FowlkesBasic Radiological Science Division, University of Michigan, Ann Arbor, MI, USA.
Ashish Kumar SahaniDepartment of Biomedical Engineering, Indian Institute of Technology, Ropar, Punjab, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Blood pressure (BP) is one of the vital physiological parameters, and its measurement is done routinely for almost all patients who visit hospitals. Cuffless BP measurement has been of great research interest over the last few years. In this paper, we aim to establish a method for cuffless measurement of BP using ultrasound. In this method, the arterial wall is pushed with an acoustic radiation force impulse (ARFI). After the completion of the ARFI pulse, the artery undergoes impulsive unloading which stimulates a hoop mode vibration. We designed two machine learning (ML) models which make it possible to estimate the internal pressure of the artery using ultrasonically measurable parameters. To generate the training data for the ML models, we did extensive finite element method (FEM) eigen frequency simulations for different tubes under pressure by sweeping through a range of values for inner lumen diameter (ILD), tube density (TD), elastic modulus, internal pressure (IP), tube length, and Poisson's ratio. Through image processing applied on images of different eigen modes supported for each simulated case, we identified its hoop mode frequency (HMF). Two different ML models were designed based on the simulated data. One is a four-parameter model (FPM) that takes tube thickness (TT), TD, ILD, and HMF as the inputs and gives out IP as output. Second is a three-parameter model (TPM) that takes TT, ILD, and HMF as inputs and IP as output. The accuracy of these models was assessed using simulated data, and their performance was confirmed through experimental verification on two arterial phantoms across a range of pressure values. The first prediction model (FPM) exhibited a mean absolute percentage error (MAPE) of 5.63% for the simulated data and 3.68% for the experimental data. The second prediction model (TPM) demonstrated a MAPE of 6.5% for simulated data and 8.73% for experimental data. We were able to create machine learning models that can measure pressure within an elastic tube through ultrasonically measurable parameters and verified their performance to be adequate for BP measurement applications. This work establishes a pathway for cuffless, continuous, real-time, and non-invasive measurement of BP using ultrasound.

Indexed as

Blood PressureBlood Pressure DeterminationMachine LearningComputer SimulationFinite Element AnalysisHumansModels, CardiovascularUltrasonographyVibrationARFIBlood pressureFEMHoop mode frequencyMachine learning

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.