ArticleMedical & biological engineering & computing2025
Machine learning models based on FEM simulation of hoop mode vibrations to enable ultrasonic cuffless measurement of blood pressure.
Article in Medical & biological engineering & computing, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Cuffless Blood Pressure Monitor for Home and Hospital Use.Sensors (Basel, Switzerland) · 2025Review
Corrections and comments
- Erratum issued
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Blood pressure (BP) is one of the vital physiological parameters, and its measurement is done routinely for almost all patients who visit hospitals. Cuffless BP measurement has been of great research interest over the last few years. In this paper, we aim to establish a method for cuffless measurement of BP using ultrasound. In this method, the arterial wall is pushed with an acoustic radiation force impulse (ARFI). After the completion of the ARFI pulse, the artery undergoes impulsive unloading which stimulates a hoop mode vibration. We designed two machine learning (ML) models which make it possible to estimate the internal pressure of the artery using ultrasonically measurable parameters. To generate the training data for the ML models, we did extensive finite element method (FEM) eigen frequency simulations for different tubes under pressure by sweeping through a range of values for inner lumen diameter (ILD), tube density (TD), elastic modulus, internal pressure (IP), tube length, and Poisson's ratio. Through image processing applied on images of different eigen modes supported for each simulated case, we identified its hoop mode frequency (HMF). Two different ML models were designed based on the simulated data. One is a four-parameter model (FPM) that takes tube thickness (TT), TD, ILD, and HMF as the inputs and gives out IP as output. Second is a three-parameter model (TPM) that takes TT, ILD, and HMF as inputs and IP as output. The accuracy of these models was assessed using simulated data, and their performance was confirmed through experimental verification on two arterial phantoms across a range of pressure values. The first prediction model (FPM) exhibited a mean absolute percentage error (MAPE) of 5.63% for the simulated data and 3.68% for the experimental data. The second prediction model (TPM) demonstrated a MAPE of 6.5% for simulated data and 8.73% for experimental data. We were able to create machine learning models that can measure pressure within an elastic tube through ultrasonically measurable parameters and verified their performance to be adequate for BP measurement applications. This work establishes a pathway for cuffless, continuous, real-time, and non-invasive measurement of BP using ultrasound.
Indexed as
Identifiers
39760966What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.