Evidence map›Paper›PMID 39760844›Full record

ArticlePhysical and engineering sciences in medicine2025

Enhancing percutaneous coronary intervention using TriVOCTNet: a multi-task deep learning model for comprehensive intravascular optical coherence tomography analysis.

Yu Shi Lau, Li Kuo Tan, Kok Han Chee, Chow Khuen Chan, Yih Miin Liew

Abstract read
PubMed Publisher
In one paragraph

Article in Physical and engineering sciences in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yu Shi LauFaculty of Engineering, Department of Biomedical Engineering, Universiti Malaya, Kuala Lumpur, Malaysia.
Li Kuo TanFaculty of Medicine, Department of Biomedical Imaging, Universiti Malaya, Kuala Lumpur, Malaysia.
Kok Han CheeFaculty of Medicine, Department of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.
Chow Khuen ChanFaculty of Engineering, Department of Biomedical Engineering, Universiti Malaya, Kuala Lumpur, Malaysia.
Yih Miin LiewFaculty of Engineering, Department of Biomedical Engineering, Universiti Malaya, Kuala Lumpur, Malaysia. liewym@um.edu.my.ORCID http://orcid.org/0000-0003-2487-3933

Funding

Malaysia Ministry of Higher Education Fundamental Research Grant Scheme FRGS/1/2018/SKK03/UM/02/1
6 · The paper itself

Abstract

Neointimal coverage and stent apposition, as assessed from intravascular optical coherence tomography (IVOCT) images, are crucial for optimizing percutaneous coronary intervention (PCI). Existing state-of-the-art computer algorithms designed to automate this analysis often treat lumen and stent segmentations as separate target entities, applicable only to a single stent type and overlook automation of preselecting which pullback segments need segmentation, thus limit their practicality. This study aimed for an algorithm capable of intelligently handling the entire IVOCT pullback across different phases of PCI and clinical scenarios, including the presence and coexistence of metal and bioresorbable vascular scaffold (BVS), stent types. We propose a multi-task deep learning model, named TriVOCTNet, that automates image classification/selection, lumen segmentation and stent struts segmentation within a single network by integrating classification, regression and pixel-level segmentation models. This approach allowed a single-network, single-pass implementation with all tasks parallelized for speed and convenience. A joint loss function was specifically designed to optimize each task in situations where each task may or may not be present. Evaluation on 4,746 images achieved classification accuracies of 0.999, 0.997, and 0.998 for lumen, BVS, and metal stent features, respectively. The lumen segmentation performance showed a Euclidean distance error of 21.72 μm and Dice's coefficient of 0.985. For BVS struts segmentation, the Dice's coefficient was 0.896, and for metal stent struts segmentation, the precision was 0.895 and sensitivity was 0.868. TriVOCTNet highlights its clinical potential due to its fast and accurate results, and simplicity in handling all tasks and scenarios through a single system.

Indexed as

Deep LearningImage Processing, Computer-AssistedPercutaneous Coronary InterventionTomography, Optical CoherenceAlgorithmsHumansStentsDeep learningIntravascular optical coherence tomographyLumen segmentationNeointimal coverageStent appositionStent struts segmentation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.