Accelerometers can correctly count orthopaedic patients' early post-operative steps while using walking aids.

Spiros Tsamassiotis, Michael Schwarze, Philipp Gehring, Roman F Karkosch, Lars-René Tücking, Ann-Kathrin Einfeldt, Eike Jakubowitz

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Spiros TsamassiotisDepartment of Orthopaedic Surgery Hannover Medical School, Diakovere Annastift Hannover Germany.ORCID 0000-0002-1628-4816
Michael SchwarzeDepartment of Orthopaedic Surgery Hannover Medical School, Laboratory for Biomechanics and Biomaterials Hannover Germany.
Philipp GehringDepartment of Orthopaedic Surgery Hannover Medical School, Laboratory for Biomechanics and Biomaterials Hannover Germany.
Roman F KarkoschDepartment of Orthopaedic Surgery Hannover Medical School, Diakovere Annastift Hannover Germany.
Lars-René TückingDepartment of Orthopaedic Surgery Hannover Medical School, Diakovere Annastift Hannover Germany.
Ann-Kathrin EinfeldtDepartment of Orthopaedic Surgery Hannover Medical School, Laboratory for Biomechanics and Biomaterials Hannover Germany.
Eike JakubowitzDepartment of Orthopaedic Surgery Hannover Medical School, Laboratory for Biomechanics and Biomaterials Hannover Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Effective rehabilitation after orthopaedic surgery is critical. The early post-operative phase is increasingly managed in outpatient settings, necessitating objective measures such as step counts to monitor rehabilitation progress. However, it remains unclear if commercially available wearables or accelerometers using simple algorithms can accurately count steps in early post-operative conditions. We hypothesised that only accelerometers could accurately determine the number of steps under these conditions. Methods: This case series involved 20 healthy subjects, 7 female and 13 males, walking in a circle at varying speeds under partial loading with three different walking aids (forearm crutches, walking frame and rolling walker) and four wearables (Vivofit 4, Fenix 3HR, Fitbit Charge 3 and Omron HJ-325) and one accelerometer (AX6) worn on the wrist, hip and ankle. The two-point and modified three-point gait patterns commonly used post-operatively were simulated. The primary end point was the relative error (RE), defined as RE = (manual count - automated count)/manual count, of each wearable measurement compared to visual and video step counting, the gold standard. Results: The RE of AX6 and Fitbit was less than 0.1 for all walking aids except the rolling walker, with AX6 showing the lowest standard deviation (SD) compared to other wearables. Other wearables had significantly higher RE. Increased gait speed generally improved accuracy, reducing RE in most devices, except for the AX6, which showed the opposite trend. At 0.6 m/s, only AX6 achieved an RE below 0.1. The ankle was identified as the best measuring location. Conclusion: During the early post-operative period, commercial wearables can only accurately count steps under specific conditions and should be used cautiously for monitoring steps in the early post-operative phase. However, accelerometers with appropriate coding appear suitable for this purpose. Level of Evidence: Level III diagnostic study.

Indexed as

accelerometeraccuracyassistive deviceearly post‐operative periodorthopaedic rehabilitationspeedstep countwalking aidwearableweight‐bearing